当前位置: 首页>>代码示例>>Python>>正文


Python OpTestHost.host_get_kernel_version方法代码示例

本文整理汇总了Python中common.OpTestHost.OpTestHost.host_get_kernel_version方法的典型用法代码示例。如果您正苦于以下问题:Python OpTestHost.host_get_kernel_version方法的具体用法?Python OpTestHost.host_get_kernel_version怎么用?Python OpTestHost.host_get_kernel_version使用的例子?那么恭喜您, 这里精选的方法代码示例或许可以为您提供帮助。您也可以进一步了解该方法所在common.OpTestHost.OpTestHost的用法示例。


在下文中一共展示了OpTestHost.host_get_kernel_version方法的11个代码示例,这些例子默认根据受欢迎程度排序。您可以为喜欢或者感觉有用的代码点赞,您的评价将有助于系统推荐出更棒的Python代码示例。

示例1: OpTestHeartbeat

# 需要导入模块: from common.OpTestHost import OpTestHost [as 别名]
# 或者: from common.OpTestHost.OpTestHost import host_get_kernel_version [as 别名]
class OpTestHeartbeat():
    ##  Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostPasswd, i_bmcIP)
        self.cv_SYSTEM = OpTestSystem(i_bmcIP, i_bmcUser, i_bmcPasswd,
                         i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostip,
                         i_hostuser, i_hostPasswd)
        self.util = OpTestUtil()

    ##
    # @brief This function will cover following test steps
    #        1. It will check for os level and get kernel version
    #        2. It will check for existence of ps command
    #        3. It will check for kopald service is running 
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_kopald_service(self):
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()

        # Get OS level
        l_oslevel = self.cv_HOST.host_get_OS_Level()

        # Get kernel version
        l_kernel = self.cv_HOST.host_get_kernel_version()

        # Checking for ps command 
        self.cv_HOST.host_check_command("ps")

        l_cmd = "ps -ef | grep -i kopald"
        print l_cmd
        l_res = self.cv_HOST.host_run_command(l_cmd)
        print l_res
        if (l_res.__contains__('[kopald]')):
            return BMC_CONST.FW_SUCCESS 
        else:
            l_msg = "kopald service is not running"
            print l_msg
            raise OpTestError(l_msg)
开发者ID:open-power,项目名称:op-test-framework,代码行数:58,代码来源:OpTestHeartbeat.py

示例2: OpTestInbandUsbInterface

# 需要导入模块: from common.OpTestHost import OpTestHost [as 别名]
# 或者: from common.OpTestHost.OpTestHost import host_get_kernel_version [as 别名]
class OpTestInbandUsbInterface():
    ##  Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the host
    # @param i_hostUser The userid to log into the host
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostIP=None,
                 i_hostUser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir)
        self.cv_HOST = OpTestHost(i_hostIP, i_hostUser, i_hostPasswd, i_bmcIP)
        self.util = OpTestUtil()

    ##
    # @brief This function will cover following test steps
    #        1. It will get the OS level installed on powernv platform
    #        2. It will check for kernel version installed on the Open Power Machine
    #        3. It will check for ipmitool command existence and ipmitool package
    #        4. Checking Inband ipmitool command functionality with different options
    #           using ipmitool usb interface.
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_ipmi_inband_usb_interface(self):
         # Get OS level
        l_oslevel = self.cv_HOST.host_get_OS_Level()

        # Get kernel version
        l_kernel = self.cv_HOST.host_get_kernel_version()

        # Checking for ipmitool command and lm_sensors package
        self.cv_HOST.host_check_command("ipmitool")

        l_pkg = self.cv_HOST.host_check_pkg_for_utility(l_oslevel, "ipmitool")
        print "Installed package: %s" % l_pkg

        # loading below ipmi modules based on config option
        # ipmi_devintf, ipmi_powernv and ipmi_masghandler
        self.cv_HOST.host_load_module_based_on_config(l_kernel, BMC_CONST.CONFIG_IPMI_DEVICE_INTERFACE,
                                                      BMC_CONST.IPMI_DEV_INTF)
        self.cv_HOST.host_load_module_based_on_config(l_kernel, BMC_CONST.CONFIG_IPMI_POWERNV,
                                                      BMC_CONST.IPMI_POWERNV)
        self.cv_HOST.host_load_module_based_on_config(l_kernel, BMC_CONST.CONFIG_IPMI_HANDLER,
                                                      BMC_CONST.IPMI_MSG_HANDLER)
        print "Inband IPMI[USB]: Chassis tests"
        self.test_chassis()
        print "Inband IPMI[USB]: Chassis Identify tests"
        self.test_chassis_identifytests()
        print "Inband IPMI[USB]: Chassis Bootdevice tests"
        self.test_chassis_bootdev()
        print "Inband IPMI[USB]: Channel tests"
        #self.test_channel()
        print "Inband IPMI[USB]: Info tests"
        self.test_Info()
        print "Inband IPMI[USB]: SDR list tests"
        self.test_sdr_list_by_type()
        print "Inband IPMI[USB]: SDR elist tests"
        self.test_sdr_elist_by_type()
        print "Inband IPMI[USB]: SDR type list tests"
        self.test_sdr_type_list()
        print "Inband IPMI[USB]: SDR get tests"
        self.test_sdr_get_id()
        print "Inband IPMI[USB]: FRU Tests"
        self.test_fru_print()
        self.test_fru_read()
        print "Inband IPMI[USB]: SEL tests"
        self.test_sel_info()
        self.test_sel_list()
        self.test_sel_elist()
        l_res = self.test_sel_time_get()
        self.test_sel_time_set(l_res[-2])
        i_num = "3"
        self.test_sel_list_first_n_entries(i_num)
        self.test_sel_list_last_n_entries(i_num)
        self.test_sel_get_functionality()
        self.test_sel_clear_functionality()
        print "Inband IPMI[USB]: MC tests"
        self.test_mc()
        print "Inband IPMI[USB]: Sensor tests"
        self.test_sensor_list()
        self.test_sensor_byid("Host Status")
        self.test_sensor_byid("OS Boot")
        self.test_sensor_byid("OCC Active")
        print "Inband IPMI[USB]: dcmi tests"
        self.test_dcmi()
        print "Inband IPMI[USB]: echo tests"
        self.test_echo()
        print "Inband IPMI[USB]: event tests"
        self.test_event()
        print "Inband IPMI[USB]: Firewall test"
#.........这里部分代码省略.........
开发者ID:shenki,项目名称:op-test-framework,代码行数:103,代码来源:OpTestInbandUsbInterface.py

示例3: OpTestI2Cdriver

# 需要导入模块: from common.OpTestHost import OpTestHost [as 别名]
# 或者: from common.OpTestHost.OpTestHost import host_get_kernel_version [as 别名]
class OpTestI2Cdriver():
    ## Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostPasswd, i_bmcIP)
        self.util = OpTestUtil()

    ##
    # @brief  This function has following test steps
    #         1. Getting host information(OS and kernel info)
    #         2. Checking the required utilites are present on host or not
    #         3. Loading the necessary modules to test I2C device driver functionalites
    #            (i2c_dev, i2c_opal and at24)
    #         4. Getting the list of i2c buses
    #         5. Querying the i2c bus for devices
    #         3. Getting the list of i2c buses and eeprom chip addresses
    #         4. Accessing the registers visible through the i2cbus using i2cdump utility
    #         5. Listing the i2c adapter conetents and i2c bus entries to make sure sysfs entries
    #            created for each bus.
    #         6. Testing i2cget functionality for limited samples
    #            Avoiding i2cset functionality, it may damage the system.
    #
    # @return BMC_CONST.FW_SUCCESS-success or raise OpTestError-fail
    #
    def testI2Cdriver(self):

        # Get OS level
        self.cv_HOST.host_get_OS_Level()

        # make sure install "i2c-tools" package in-order to run the test

        # Check whether i2cdump, i2cdetect and hexdump commands are available on host
        self.cv_HOST.host_check_command("i2cdump")
        self.cv_HOST.host_check_command("i2cdetect")
        self.cv_HOST.host_check_command("hexdump")
        self.cv_HOST.host_check_command("i2cget")
        self.cv_HOST.host_check_command("i2cset")

        # Get Kernel Version
        l_kernel = self.cv_HOST.host_get_kernel_version()

        # loading i2c_opal module based on config option
        l_config = "CONFIG_I2C_OPAL"
        l_module = "i2c_opal"
        self.cv_HOST.host_load_module_based_on_config(l_kernel, l_config, l_module)

        # loading i2c_dev module based on config option
        l_config = "CONFIG_I2C_CHARDEV"
        l_module = "i2c_dev"
        self.cv_HOST.host_load_module_based_on_config(l_kernel, l_config, l_module)

        # loading at24 module based on config option
        l_config = "CONFIG_EEPROM_AT24"
        l_module = "at24"
        self.cv_HOST.host_load_module_based_on_config(l_kernel, l_config, l_module)

        # Get information of EEPROM chips
        self.cv_HOST.host_get_info_of_eeprom_chips()

        # Get list of i2c buses available on host,
        # l_list=["0","1"....]
        # l_list1=["i2c-0","i2c-1","i2c-2"....]
        l_list, l_list1 = self.cv_HOST.host_get_list_of_i2c_buses()

        # Scanning i2c bus for devices attached to it.
        for l_bus in l_list:
            self.query_i2c_bus(l_bus)

        # Get list of pairs of i2c bus and EEPROM device addresses in the host
        l_chips = self.cv_HOST.host_get_list_of_eeprom_chips()
        for l_args in l_chips:
            # Accessing the registers visible through the i2cbus using i2cdump utility
            # l_args format: "0 0x51","1 0x53",.....etc
            self.i2c_dump(l_args)

        # list i2c adapter conetents
        l_res = self.cv_HOST.host_run_command("ls -l /sys/class/i2c-adapter; echo $?")
        l_res = l_res.splitlines()
        if int(l_res[-1]) == 0:
            pass
        else:
            l_msg = "listing i2c adapter contents through the sysfs entry failed"
            print l_msg
            raise OpTestError(l_msg)
#.........这里部分代码省略.........
开发者ID:shenki,项目名称:op-test-framework,代码行数:103,代码来源:OpTestI2Cdriver.py

示例4: OpTestOOBIPMI

# 需要导入模块: from common.OpTestHost import OpTestHost [as 别名]
# 或者: from common.OpTestHost.OpTestHost import host_get_kernel_version [as 别名]
class OpTestOOBIPMI():
    ##  Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostPasswd, i_bmcIP)
        self.cv_SYSTEM = OpTestSystem(i_bmcIP, i_bmcUser, i_bmcPasswd,
                                      i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostip,
                                      i_hostuser, i_hostPasswd)
        self.util = OpTestUtil()

    ##
    # @brief  It will execute and test all Out-of-band ipmi commands.
    #         bmc, channel, chassis, dcmi, echo, event, exec, firewall, fru, lan
    #         mc, pef, power, raw, sdr, sel, sensor, session, user
    #
    # @return l_res @type list: output of command or raise OpTestError
    #
    def test_oob_ipmi(self):
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()
         # Get OS level
        l_oslevel = self.cv_HOST.host_get_OS_Level()

        # Get kernel version
        l_kernel = self.cv_HOST.host_get_kernel_version()

        # Checking for ipmitool command and lm_sensors package
        self.cv_HOST.host_check_command("ipmitool")

        l_pkg = self.cv_HOST.host_check_pkg_for_utility(l_oslevel, "ipmitool")
        print "Installed package: %s" % l_pkg

        # loading below ipmi modules based on config option
        # ipmi_devintf, ipmi_powernv and ipmi_masghandler
        self.cv_HOST.host_load_module_based_on_config(l_kernel, BMC_CONST.CONFIG_IPMI_DEVICE_INTERFACE,
                                                      BMC_CONST.IPMI_DEV_INTF)
        self.cv_HOST.host_load_module_based_on_config(l_kernel, BMC_CONST.CONFIG_IPMI_POWERNV,
                                                      BMC_CONST.IPMI_POWERNV)
        self.cv_HOST.host_load_module_based_on_config(l_kernel, BMC_CONST.CONFIG_IPMI_HANDLER,
                                                      BMC_CONST.IPMI_MSG_HANDLER)

        test_cases = [self.test_chassis, self.test_chassisIdentifytests,
        self.test_chassisBootdev, self.test_Info, self.test_sdr_list_by_type,
        self.test_sdr_elist_by_type, self.test_sdr_type_list, self.test_sdr_get_id,
        self.test_fru_print, self.test_fru_read, self.test_mc,
        self.test_sensor_list, self.test_sensor_get_host_status,
        self.test_sensor_get_os_boot, self.test_sel_info, self.test_sel_list,
        self.test_sel_elist, self.test_set_sel_time,
        self.test_sel_time_get, self.test_sel_list_first_3_entries,
        self.test_sel_list_last_3_entries, self.test_sel_get_functionality,
        self.test_sel_clear_functionality, self.test_channel,
        self.test_dcmi, self.test_echo, self.test_event,
        self.test_firewall, self.test_pef, self.test_raw,
        self.test_exec, self.test_bmc_golden_side_version,
        self.test_get_pnor_partition_size_cmd,
        self.test_bmc_boot_completed_cmd,
        self.test_get_led_state_cmd, self.test_set_led_state_cmd]

        fail_count = 0

        for test in test_cases:
            try:
                print "OOB IPMI: test case %s" % test
                test(self)
            except:
                print "Test Fail: %s failed" % test
                fail_count += 1
                print sys.exc_info()
                continue

        print "OOB IPMI: Test case failure count %s" % fail_count

        print self.cv_IPMI.ipmi_get_bmc_golden_side_version()
        print self.cv_IPMI.ipmi_get_pnor_partition_size("NVRAM")
        print self.cv_IPMI.ipmi_get_pnor_partition_size("GUARD")
        print self.cv_IPMI.ipmi_get_pnor_partition_size("BOOTKERNEL")
        print self.cv_IPMI.ipmi_get_bmc_boot_completion_status()
        print self.cv_IPMI.ipmi_get_fault_led_state()
        print self.cv_IPMI.ipmi_get_power_on_led_state()
        print self.cv_IPMI.ipmi_get_host_status_led_state()
        print self.cv_IPMI.ipmi_get_chassis_identify_led_state()
        self.cv_IPMI.ipmi_enable_fan_control_task_command()
        self.cv_IPMI.ipmi_get_fan_control_task_state_command()
        self.cv_IPMI.ipmi_disable_fan_control_task_command()
        self.cv_IPMI.ipmi_get_fan_control_task_state_command()
#.........这里部分代码省略.........
开发者ID:open-power,项目名称:op-test-framework,代码行数:103,代码来源:OpTestOOBIPMI.py

示例5: OpTestRTCdriver

# 需要导入模块: from common.OpTestHost import OpTestHost [as 别名]
# 或者: from common.OpTestHost.OpTestHost import host_get_kernel_version [as 别名]
class OpTestRTCdriver():
    ##  Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostPasswd,i_bmcIP)
        self.util = OpTestUtil()

    ##
    # @brief This function will cover following test steps
    #        1. Getting host information(OS and Kernel info)
    #        2. Loading rtc_opal module based on config option
    #        3. Testing the rtc driver functions
    #                Display the current time,
    #                set the Hardware Clock to a specified time,
    #                set the Hardware Clock from the System Time, or
    #                set the System Time from the Hardware Clock
    #                keep the Hardware clock in UTC or local time format
    #                Hardware clock compare, predict and adjust functions
    #                Hardware clock debug and test modes
    #                Reading the Hardware clock from special file instead of default
    #        4. After executing above each function reading the Hardware clock in b/w functions.
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_RTC_driver(self):

        # Get OS level
        l_oslevel = self.cv_HOST.host_get_OS_Level()

        # Get Kernel Version
        l_kernel = self.cv_HOST.host_get_kernel_version()

        # Get hwclock version
        l_hwclock = self.cv_HOST.host_run_command("hwclock -V;echo $?")

        # loading rtc_opal module based on config option
        l_config = "CONFIG_RTC_DRV_OPAL"
        l_module = "rtc_opal"
        self.cv_HOST.host_load_module_based_on_config(l_kernel, l_config, l_module)

        # Get the device files for rtc driver
        l_res = self.cv_HOST.host_run_command("ls /dev/ | grep -i --color=never rtc")
        l_files = l_res.splitlines()
        l_list = []
        for name in l_files:
            if name.__contains__("rtc"):
                l_file = "/dev/" + name
                l_list.append(l_file)
            else:
                continue
        print l_list

        # Display the time of hwclock from device files
        for l_file in l_list:
            self.read_hwclock_from_file(l_file)

        self.cv_HOST.host_read_hwclock()
        time.sleep(5)
        self.cv_HOST.host_set_hwclock_time("2015-01-01 10:10:10")
        time.sleep(5)
        self.cv_HOST.host_read_hwclock()
        self.cv_HOST.host_set_hwclock_time("2016-01-01 20:20:20")
        self.cv_HOST.host_read_hwclock()
        self.set_hwclock_in_utc("2017-01-01 10:10:10")
        self.cv_HOST.host_read_hwclock()
        self.set_hwclock_in_localtime("2014-01-01 05:05:05")
        self.cv_HOST.host_read_hwclock()
        self.cv_HOST.host_read_systime()
        self.systime_to_hwclock()
        self.cv_HOST.host_read_hwclock()
        self.systime_to_hwclock_in_utc()
        self.cv_HOST.host_read_hwclock()
        self.systime_to_hwclock_in_localtime()
        self.cv_HOST.host_read_hwclock()
        self.hwclock_to_systime()
        self.cv_HOST.host_read_hwclock()
        self.cv_HOST.host_read_systime()
        self.hwclock_in_utc()
        self.cv_HOST.host_read_hwclock()
        self.hwclock_in_localtime()
        self.cv_HOST.host_read_hwclock()
        self.hwclock_predict("2015-01-01 10:10:10")
        self.cv_HOST.host_read_hwclock()
        self.hwclock_debug_mode()
#.........这里部分代码省略.........
开发者ID:shenki,项目名称:op-test-framework,代码行数:103,代码来源:OpTestRTCdriver.py

示例6: OpTestInbandIPMI

# 需要导入模块: from common.OpTestHost import OpTestHost [as 别名]
# 或者: from common.OpTestHost.OpTestHost import host_get_kernel_version [as 别名]
class OpTestInbandIPMI():
    ##  Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostPasswd, i_bmcIP)
        self.util = OpTestUtil()

    ##
    # @brief This function will cover following test steps
    #        1. It will get the OS level installed on powernv platform
    #        2. It will check for kernel version installed on the Open Power Machine 
    #        3. It will check for ipmitool command existence and ipmitool package
    #        4. Checking Inband ipmitool command functionality with different options
    #           using ipmitool.
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_ipmi_inband_functionality(self):

        # Get OS level
        l_oslevel = self.cv_HOST.host_get_OS_Level()

        # Get kernel version
        l_kernel = self.cv_HOST.host_get_kernel_version()

        # Checking for ipmitool command and lm_sensors package
        self.cv_HOST.host_check_command("ipmitool")

        l_pkg = self.cv_HOST.host_check_pkg_for_utility(l_oslevel, "ipmitool")
        print "Installed package: %s" % l_pkg


        # Checking Inband ipmitool command functionality with different options
        l_cmd = "ipmitool sdr; echo $?"
        output = self.cv_HOST.host_run_command(l_cmd)
        response = output.splitlines()
        if int(response[-1]):
            l_msg = "ipmitool sdr not working,exiting...."
            raise OpTestError(l_msg)

        l_cmd = "ipmitool sdr elist full; echo $?"
        output = self.cv_HOST.host_run_command(l_cmd)
        response = output.splitlines()
        if int(response[-1]):
            l_msg = "ipmitool sdr elist full not working,exiting...."
            raise OpTestError(l_msg)

        l_cmd = "ipmitool sdr type temperature; echo $?"
        l_res = self.cv_HOST.host_run_command(l_cmd)
        if l_res.__contains__("Temp"):
            print "ipmitool sdr type temperature is working"
        else:
            l_msg = "ipmitool sdr type temperature is not working"
            raise OpTestError(l_msg)


        l_cmd = "ipmitool lan print 1; echo $?"
        output = self.cv_HOST.host_run_command(l_cmd)
        response = output.splitlines()
        if int(response[-1]):
            l_msg = "ipmitool lan print command is not working,exiting...."
            raise OpTestError(l_msg)


        l_cmd = "ipmitool fru print; echo $?"
        output = self.cv_HOST.host_run_command(l_cmd)
        response = output.splitlines()
        if int(response[-1]):
            l_msg = "ipmitool fru print is not working,exiting...."
            raise OpTestError(l_msg)


        l_cmd = "ipmitool chassis status | grep \"System Power\""
        l_res = self.cv_HOST.host_run_command(l_cmd)
        if l_res.__contains__("System Power         : on"):
            print "ipmitool Chassis status is working"
        else:
            l_msg = "ipmitool chassis status is not working"
            raise OpTestError(l_msg)

        l_cmd = "ipmitool chassis identify 1; echo $?"
        l_res = self.cv_HOST.host_run_command(l_cmd)
        if l_res.__contains__("Chassis identify interval: 1 seconds"):
            print "ipmitool Chassis identify interval is working"
#.........这里部分代码省略.........
开发者ID:shenki,项目名称:op-test-framework,代码行数:103,代码来源:OpTestInbandIPMI.py

示例7: OpTestAt24driver

# 需要导入模块: from common.OpTestHost import OpTestHost [as 别名]
# 或者: from common.OpTestHost.OpTestHost import host_get_kernel_version [as 别名]
class OpTestAt24driver():
    ## Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostPasswd,i_bmcIP)
        self.cv_SYSTEM = OpTestSystem(i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostip,
                 i_hostuser, i_hostPasswd)
        self.util = OpTestUtil()

    ##
    # @brief  This function has following test steps
    #         1. Getting the host infromation(OS and kernel information)
    #         2. Loading the necessary modules to test at24 device driver functionalites
    #            (i2c_dev, i2c_opal and at24)
    #         3. Getting the list of i2c buses and eeprom chip addresses
    #         4. Accessing the registers visible through the i2cbus using i2cdump utility
    #         5. Getting the eeprom device data using hexdump utility in hex + Ascii format
    #
    # @return BMC_CONST.FW_SUCCESS-success or raise OpTestError
    #
    def testAt24driver(self):
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()
        # Get OS level
        self.cv_HOST.host_get_OS_Level()

        # Check whether i2cdump and hexdump commands are available on host
        self.cv_HOST.host_check_command("i2cdump", "hexdump")

        # Get Kernel Version
        l_kernel = self.cv_HOST.host_get_kernel_version()

        # Loading i2c_opal module based on config option
        l_config = "CONFIG_I2C_OPAL"
        l_module = "i2c_opal"
        self.cv_HOST.host_load_module_based_on_config(l_kernel, l_config, l_module)

        # Loading i2c_dev module based on config option
        l_config = "CONFIG_I2C_CHARDEV"
        l_module = "i2c_dev"
        self.cv_HOST.host_load_module_based_on_config(l_kernel, l_config, l_module)

        # Loading at24 module based on config option
        l_config = "CONFIG_EEPROM_AT24"
        l_module = "at24"
        self.cv_HOST.host_load_module_based_on_config(l_kernel, l_config, l_module)

        # Get infomtion of EEPROM chips
        self.cv_HOST.host_get_info_of_eeprom_chips()

        # Get list of pairs of i2c bus and EEPROM device addresses in the host
        l_chips = self.cv_HOST.host_get_list_of_eeprom_chips()
        for l_args in l_chips:
            # Accessing the registers visible through the i2cbus using i2cdump utility
            # l_args format: "0 0x51","1 0x53",.....etc
            self.i2c_dump(l_args)

        # Getting the list of sysfs eeprom interfaces
        l_res = self.cv_HOST.host_run_command("find /sys/ -name eeprom; echo $?")
        l_res = l_res.splitlines()
        if int(l_res[-1]) == 0:
            pass
        else:
            l_msg = "EEPROM sysfs entries are not created"
            print l_msg
            raise OpTestError(l_msg)
        for l_dev in l_res:
            if l_dev.__contains__("eeprom"):
                # Getting the eeprom device data using hexdump utility in hex + Ascii format
                self.cv_HOST.host_hexdump(l_dev)
            else:
                pass
        return BMC_CONST.FW_SUCCESS

    ##
    # @brief This i2cdump function takes arguments in pair of a string like "i2cbus address".
    #        i2cbus indicates the number or name of the I2C bus to be scanned. This number should
    #        correspond  to  one  of  the busses listed by i2cdetect -l. address indicates
    #        the address to be scanned on that bus, and is an integer between 0x03 and 0x77
    #        i2cdump is a program to examine registers visible through the I2C bus
    #
    # @param i_args @type string: this is the argument to i2cdump utility
    #                             args are in the form of "i2c-bus-number eeprom-chip-address"
    #                             Ex: "0 0x51","3 0x52" ....etc
#.........这里部分代码省略.........
开发者ID:open-power,项目名称:op-test-framework,代码行数:103,代码来源:OpTestAt24driver.py

示例8: OpTestSensors

# 需要导入模块: from common.OpTestHost import OpTestHost [as 别名]
# 或者: from common.OpTestHost.OpTestHost import host_get_kernel_version [as 别名]
class OpTestSensors():
    ##  Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostPasswd,i_bmcIP)
        self.util = OpTestUtil()

    ##
    # @brief This function will cover following test steps
    #        1. It will check for kernel config option CONFIG_SENSORS_IBMPOWERNV
    #        2. It will load ibmpowernv driver only on powernv platform
    #        3. It will check for sensors command existence and lm_sensors package
    #        4. start the lm_sensors service and detect any sensor chips
    #           using sensors-detect.
    #        5. At the end it will test sensors command functionality
    #           with different options
    #
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_hwmon_driver(self):

        # Get OS level
        l_oslevel = self.cv_HOST.host_get_OS_Level()

        # Get kernel version
        l_kernel = self.cv_HOST.host_get_kernel_version()

        # Checking for sensors config option CONFIG_SENSORS_IBMPOWERNV
        l_config = "CONFIG_SENSORS_IBMPOWERNV"

        l_val = self.cv_HOST.host_check_config(l_kernel, l_config)
        if l_val == "y":
            print "Driver build into kernel itself"
        else:
            print "Driver will be built as module"

        # Loading ibmpowernv driver only on powernv platform
        self.cv_HOST.host_load_ibmpowernv(l_oslevel)

        # Checking for sensors command and lm_sensors package
        self.cv_HOST.host_check_command("sensors")

        l_pkg = self.cv_HOST.host_check_pkg_for_utility(l_oslevel, "sensors")
        print "Installed package: %s" % l_pkg

        # Restart the lm_sensor service
        self.cv_HOST.host_start_lm_sensor_svc(l_oslevel)

        # To detect different sensor chips and modules
        res = self.cv_HOST.host_run_command("yes | sensors-detect")
        print res

        # Checking sensors command functionality with different options
        output = self.cv_HOST.host_run_command("sensors; echo $?")
        response = output.splitlines()
        if int(response[-1]):
            l_msg = "sensors not working,exiting...."
            raise OpTestError(l_msg)
        print output
        output = self.cv_HOST.host_run_command("sensors -f; echo $?")
        response = output.splitlines()
        if int(response[-1]):
            l_msg = "sensors -f not working,exiting...."
            raise OpTestError(l_msg)
        print output
        output = self.cv_HOST.host_run_command("sensors -A; echo $?")
        response = output.splitlines()
        if int(response[-1]):
            l_msg = "sensors -A not working,exiting...."
            raise OpTestError(l_msg)
        print output
        output = self.cv_HOST.host_run_command("sensors -u; echo $?")
        response = output.splitlines()
        if int(response[-1]):
            l_msg = "sensors -u not working,exiting...."
            raise OpTestError(l_msg)
        print output
        return BMC_CONST.FW_SUCCESS
开发者ID:shenki,项目名称:op-test-framework,代码行数:97,代码来源:OpTestSensors.py

示例9: OpTestMtdPnorDriver

# 需要导入模块: from common.OpTestHost import OpTestHost [as 别名]
# 或者: from common.OpTestHost.OpTestHost import host_get_kernel_version [as 别名]
class OpTestMtdPnorDriver():
    ## Initialize this object and also getting the host login credentials to use by scp utility
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostPasswd, i_bmcIP)
        self.cv_SYSTEM = OpTestSystem(i_bmcIP, i_bmcUser, i_bmcPasswd,
                         i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostip,
                         i_hostuser, i_hostPasswd)
        self.util = OpTestUtil()
        self.host_user = i_hostuser
        self.host_ip = i_hostip
        self.host_Passwd = i_hostPasswd

    ##
    # @brief  This function has following test steps
    #         1. Get host information(OS and Kernel information)
    #         2. Load the mtd module based on config value
    #         3. Check /dev/mtd0 character device file existence on host
    #         4. Copying the contents of the flash in a file /tmp/pnor
    #         5. Getting the /tmp/pnor file into local x86 machine using scp utility
    #         6. Remove existing /tmp/ffs directory and
    #            Clone latest ffs git repository in local x86 working machine
    #         7. Compile ffs repository to get fcp utility
    #         8. Check existence of fcp utility in ffs repository, after compiling
    #         9. Get the PNOR flash contents on an x86 machine using fcp utility
    #
    # @return BMC_CONST.FW_SUCCESS-success or raise OpTestError-fail
    #
    def testMtdPnorDriver(self):
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()
        # Get OS level
        l_oslevel = self.cv_HOST.host_get_OS_Level()

        # Get Kernel Version
        l_kernel = self.cv_HOST.host_get_kernel_version()

        # loading mtd module based on config option
        l_config = "CONFIG_MTD_POWERNV_FLASH"
        l_module = "mtd"
        self.cv_HOST.host_load_module_based_on_config(l_kernel, l_config, l_module)

        # Check /dev/mtd0 file existence on host
        l_cmd = "ls -l /dev/mtd0; echo $?"
        l_res = self.cv_HOST.host_run_command(l_cmd)
        l_res = l_res.splitlines()
        if int(l_res[-1]) == 0:
            print "/dev/mtd0 character device file exists on host"
        else:
            l_msg = "/dev/mtd0 character device file doesn't exist on host"
            print l_msg
            raise OpTestError(l_msg)

        # Copying the contents of the PNOR flash in a file /tmp/pnor
        l_file = "/tmp/pnor"
        l_cmd = "cat /dev/mtd0 > %s; echo $?" % l_file
        l_res = self.cv_HOST.host_run_command(l_cmd)
        l_res = l_res.splitlines()
        if int(l_res[-1]) == 0:
            print "Fetched PNOR data from /dev/mtd0 into temp file /tmp/pnor"
        else:
            l_msg = "Fetching PNOR data is failed from /dev/mtd0 into temp file /tmp/pnor"
            print l_msg
            raise OpTestError(l_msg)

        # Getting the /tmp/pnor file into local x86 machine
        l_path = "/tmp/"
        self.util.copyFilesToDest(l_path, self.host_user, self.host_ip, l_file, self.host_Passwd, "2", BMC_CONST.SCP_TO_LOCAL)
        l_list =  commands.getstatusoutput("ls -l %s; echo $?" % l_path)
        print l_list

        l_workdir = "/tmp/ffs"
        # Remove existing /tmp/ffs directory
        l_res = commands.getstatusoutput("rm -rf %s" % l_workdir)
        print l_res

        # Clone latest ffs git repository in local x86 working machine
        l_cmd = "git clone   https://github.com/open-power/ffs/ %s" % l_workdir
        l_res = commands.getstatusoutput(l_cmd)
        print l_res
        if int(l_res[0]) == 0:
            print "Cloning of ffs repository is successfull"
        else:
            l_msg = "Cloning ffs repository is failed"
            print l_msg
#.........这里部分代码省略.........
开发者ID:open-power,项目名称:op-test-framework,代码行数:103,代码来源:OpTestMtdPnorDriver.py

示例10: OpTestEM

# 需要导入模块: from common.OpTestHost import OpTestHost [as 别名]
# 或者: from common.OpTestHost.OpTestHost import host_get_kernel_version [as 别名]
class OpTestEM():
    ##  Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostPasswd, i_bmcIP)
        self.cv_SYSTEM = OpTestSystem(i_bmcIP, i_bmcUser, i_bmcPasswd,
                         i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostip,
                         i_hostuser, i_hostPasswd)
        self.util = OpTestUtil()

    ##
    # @brief This function will cover following test steps
    #        1. It will get the OS and kernel versions.
    #        2. Check the cpupower utility is available in host.
    #        3. Get available cpu scaling frequencies
    #        4. Set the userspace governer for all cpu's
    #        5. test the cpufreq driver by set/verify cpu frequency
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_cpu_freq_states(self):
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()

        # Get OS level
        l_oslevel = self.cv_HOST.host_get_OS_Level()

        # Get kernel version
        l_kernel = self.cv_HOST.host_get_kernel_version()

        self.cv_HOST.host_check_command("cpupower")
        # Get available cpu scaling frequencies
        l_res = self.cv_HOST.host_run_command("cat /sys/devices/system/cpu/cpu0/cpufreq/scaling_available_frequencies")
        freq_list = (l_res.strip()).split(' ')
        print freq_list

        # Set the cpu governer to userspace
        self.set_cpu_gov("userspace")
        self.verify_cpu_gov("userspace")
        for i in range(1, 100):
            i_freq = random.choice(freq_list)
            self.set_cpu_freq(i_freq)
            self.verify_cpu_freq(i_freq)

        return BMC_CONST.FW_SUCCESS

    ##
    # @brief This function will cover following test steps
    #        1. It will get the OS and kernel versions.
    #        2. Check the cpupower utility is available in host.
    #        3. Set the userspace governer for all cpu's
    #        4. test the cpuidle driver by enable/disable/verify the idle states
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_cpu_idle_states(self):
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()

        # Get OS level
        l_oslevel = self.cv_HOST.host_get_OS_Level()

        # Get kernel version
        l_kernel = self.cv_HOST.host_get_kernel_version()

        self.cv_HOST.host_check_command("cpupower")
        # currently p8 cpu has 3 states
        for i in (0, 1, 2):
            self.enable_idle_state(i)
            self.verify_enable_idle_state(i)
        for i in (0, 1, 2):
            self.disable_idle_state(i)
            self.verify_disable_idle_state(i)

        return BMC_CONST.FW_SUCCESS

    ##
    # @brief sets the cpu frequency with i_freq value
    #
    # @param i_freq @type str: this is the frequency of cpu to be set
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def set_cpu_freq(self, i_freq):
        l_cmd = "for i in /sys/devices/system/cpu/cpu*/cpufreq/scaling_setspeed; do echo %s > $i; done" % i_freq
        self.cv_HOST.host_run_command(l_cmd)
#.........这里部分代码省略.........
开发者ID:open-power,项目名称:op-test-framework,代码行数:103,代码来源:OpTestEM.py

示例11: OpTestIPMILockMode

# 需要导入模块: from common.OpTestHost import OpTestHost [as 别名]
# 或者: from common.OpTestHost.OpTestHost import host_get_kernel_version [as 别名]
class OpTestIPMILockMode():
    ##  Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir, i_hostip, i_hostuser, i_hostPasswd)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostPasswd, i_bmcIP)
        self.cv_SYSTEM = OpTestSystem(i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostip,
                 i_hostuser, i_hostPasswd)
        self.util = OpTestUtil()

    ##
    # @brief This function will cover following test steps
    #        1. It will get the OS level installed on power platform
    #        2. It will check for kernel version installed on the Open Power Machine
    #        3. It will check for ipmitool command existence and ipmitool package
    #        4. Load the necessary ipmi modules based on config values
    #        5. Issue a ipmi lock command through out-of-band authenticated interface
    #        6. Now BMC IPMI is in locked mode, at this point only white listed
    #           in-band ipmi commands sholud work(No other in-band ipmi command should work)
    #        7. Execute and test the functionality of whitelisted in-band ipmi
    #           commands in locked mode
    #        8. At the end of test issue a ipmi unlock command to revert the availablity of all
    #           in-band ipmi commands in unlocked mode.
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_ipmi_lock_mode(self):
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()

        # Get OS level
        l_oslevel = self.cv_HOST.host_get_OS_Level()

        # Get kernel version
        l_kernel = self.cv_HOST.host_get_kernel_version()

        # Checking for ipmitool command and lm_sensors package
        self.cv_HOST.host_check_command("ipmitool")

        l_pkg = self.cv_HOST.host_check_pkg_for_utility(l_oslevel, "ipmitool")
        print "Installed package: %s" % l_pkg

        # loading below ipmi modules based on config option
        # ipmi_devintf, ipmi_powernv and ipmi_masghandler
        self.cv_HOST.host_load_module_based_on_config(l_kernel, BMC_CONST.CONFIG_IPMI_DEVICE_INTERFACE,
                                                      BMC_CONST.IPMI_DEV_INTF)
        self.cv_HOST.host_load_module_based_on_config(l_kernel, BMC_CONST.CONFIG_IPMI_POWERNV,
                                                      BMC_CONST.IPMI_POWERNV)
        self.cv_HOST.host_load_module_based_on_config(l_kernel, BMC_CONST.CONFIG_IPMI_HANDLER,
                                                      BMC_CONST.IPMI_MSG_HANDLER)

        # Issue a ipmi lock command through authenticated interface
        print "Issuing ipmi lock command through authenticated interface"
        l_res = self.cv_IPMI.ipmitool_execute_command(BMC_CONST.IPMI_LOCK_CMD)
        l_res = l_res.splitlines()
        if int(l_res[-1]):
            l_msg = "IPMI:Lock command failed, There may be two reasons here.\n\
                a. check the corresponding parches available in AMI driver code,\n\
                b. if patches available then command is failing"
            print l_msg
            raise OpTestError(l_msg)
        print "IPMI:Lock command executed successfully"

        try:
            self.run_inband_ipmi_whitelisted_cmds()
        except:
            l_msg = "One of white listed in-band ipmi command execution failed"
            print sys.exc_info()
        finally:
            # Issue a ipmi unlock command at the end of test.
            print "Issuing ipmi unlock command through authenticated interface"
            self.cv_IPMI.ipmitool_execute_command(BMC_CONST.IPMI_UNLOCK_CMD)

    ##
    # @brief This function will execute whitelisted in-band ipmi commands
    #        and test the functionality in locked mode.
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def run_inband_ipmi_whitelisted_cmds(self):
        l_con = self.cv_SYSTEM.sys_get_ipmi_console()
        self.cv_IPMI.ipmi_host_login(l_con)
        self.cv_IPMI.ipmi_host_set_unique_prompt(l_con)
        self.cv_IPMI.run_host_cmd_on_ipmi_console("uname -a")

#.........这里部分代码省略.........
开发者ID:open-power,项目名称:op-test-framework,代码行数:103,代码来源:OpTestIPMILockMode.py


注:本文中的common.OpTestHost.OpTestHost.host_get_kernel_version方法示例由纯净天空整理自Github/MSDocs等开源代码及文档管理平台,相关代码片段筛选自各路编程大神贡献的开源项目,源码版权归原作者所有,传播和使用请参考对应项目的License;未经允许,请勿转载。