示例1: OpTestSystemBootSequence
# 需要导入模块: from common.OpTestIPMI import OpTestIPMI [as 别名]
# 或者: from common.OpTestIPMI.OpTestIPMI import ipmi_warm_reset [as 别名]
class OpTestSystemBootSequence():
## Initialize this object
# @param i_bmcIP The IP address of the BMC
# @param i_bmcUser The userid to log into the BMC with
# @param i_bmcPasswd The password of the userid to log into the BMC with
# @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
# @param i_bmcPasswdIpmi The password of BMC IPMI userid
# @param i_ffdcDir Optional param to indicate where to write FFDC
#
# "Only required for inband tests" else Default = None
# @param i_hostip The IP address of the HOST
# @param i_hostuser The userid to log into the HOST
# @param i_hostpasswd The password of the userid to log into the HOST with
#
def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
i_hostuser=None, i_hostpasswd=None):
self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
i_ffdcDir, i_hostip, i_hostuser, i_hostpasswd)
self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostpasswd, i_bmcIP, i_ffdcDir)
self.cv_SYSTEM = OpTestSystem(i_bmcIP, i_bmcUser, i_bmcPasswd,
i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostip,
i_hostuser, i_hostpasswd)
self.util = OpTestUtil()
##
# @brief This function will test mc cold reset boot sequence
# It has below steps
# 1. Do a system Power OFF(Host should go down)
# 2. Set auto reboot policy to off(chassis policy always-off)
# 3. Issue a BMC Cold reset.
# 4. After BMC comes up, Issue a Power ON of the system
# 5. Check for system status and gather OPAL msg log.
#
# @return BMC_CONST.FW_SUCCESS or raise OpTestError
#
def testMcColdResetBootSequence(self):
self.cv_SYSTEM.sys_bmc_power_on_validate_host()
print "Testing MC Cold reset boot sequence"
print "Performing a IPMI Power OFF Operation"
# Perform a IPMI Power OFF Operation(Immediate Shutdown)
self.cv_IPMI.ipmi_power_off()
if int(self.cv_SYSTEM.sys_wait_for_standby_state(BMC_CONST.SYSTEM_STANDBY_STATE_DELAY)) == 0:
print "System is in standby/Soft-off state"
else:
l_msg = "System failed to reach standby/Soft-off state"
raise OpTestError(l_msg)
print "Setting the system power policy to always-off"
self.cv_IPMI.ipmi_set_power_policy("always-off")
# Perform a BMC Cold Reset Operation
self.cv_IPMI.ipmi_cold_reset()
print "Performing a IPMI Power ON Operation"
# Perform a IPMI Power ON Operation
self.cv_IPMI.ipmi_power_on()
self.cv_SYSTEM.sys_check_host_status()
self.util.PingFunc(self.cv_HOST.ip, BMC_CONST.PING_RETRY_POWERCYCLE)
self.cv_IPMI.clear_ssh_keys(self.cv_HOST.ip)
print "Gathering the OPAL msg logs"
self.cv_HOST.host_gather_opal_msg_log()
return BMC_CONST.FW_SUCCESS
##
# @brief This function will test mc warm reset boot sequence
# It has below steps
# 1. Do a system Power OFF(Host should go down)
# 2. Set auto reboot policy to off(chassis policy always-off)
# 3. Issue a BMC Warm reset.
# 4. After BMC comes up, Issue a Power ON of the system
# 5. Check for system status and gather OPAL msg log.
#
# @return BMC_CONST.FW_SUCCESS or raise OpTestError
#
def testMcWarmResetBootSequence(self):
self.cv_SYSTEM.sys_bmc_power_on_validate_host()
print "Testing MC Warm reset boot sequence"
print "Performing a IPMI Power OFF Operation"
# Perform a IPMI Power OFF Operation(Immediate Shutdown)
self.cv_IPMI.ipmi_power_off()
if int(self.cv_SYSTEM.sys_wait_for_standby_state(BMC_CONST.SYSTEM_STANDBY_STATE_DELAY)) == 0:
print "System is in standby/Soft-off state"
else:
l_msg = "System failed to reach standby/Soft-off state"
raise OpTestError(l_msg)
print "Setting the system power policy to always-off"
self.cv_IPMI.ipmi_set_power_policy("always-off")
# Perform a BMC Warm Reset Operation
self.cv_IPMI.ipmi_warm_reset()
print "Performing a IPMI Power ON Operation"
# Perform a IPMI Power ON Operation
self.cv_IPMI.ipmi_power_on()
self.cv_SYSTEM.sys_check_host_status()
self.util.PingFunc(self.cv_HOST.ip, BMC_CONST.PING_RETRY_POWERCYCLE)
self.cv_IPMI.clear_ssh_keys(self.cv_HOST.ip)
#.........这里部分代码省略.........