本文整理汇总了C#中CodeWriter.Dedent方法的典型用法代码示例。如果您正苦于以下问题:C# CodeWriter.Dedent方法的具体用法?C# CodeWriter.Dedent怎么用?C# CodeWriter.Dedent使用的例子?那么恭喜您, 这里精选的方法代码示例或许可以为您提供帮助。您也可以进一步了解该方法所在类CodeWriter
的用法示例。
在下文中一共展示了CodeWriter.Dedent方法的1个代码示例,这些例子默认根据受欢迎程度排序。您可以为喜欢或者感觉有用的代码点赞,您的评价将有助于系统推荐出更棒的C#代码示例。
示例1: GenerateReader
//.........这里部分代码省略.........
cw.WriteLine("limit += stream.Position;");
}
if (method == "DeserializeLength")
{
//Important to read stream position after we have read the length field
cw.WriteLine("long limit = stream.Position + length;");
}
cw.WhileBracket("true");
if (method == "DeserializeLengthDelimited" || method == "DeserializeLength")
{
cw.IfBracket("stream.Position >= limit");
cw.WriteLine("if (stream.Position == limit)");
cw.WriteIndent("break;");
cw.WriteLine("else");
cw.WriteIndent("throw new InvalidOperationException(\"Read past max limit\");");
cw.EndBracket();
}
cw.WriteLine("int keyByte = stream.ReadByte();");
cw.WriteLine("if (keyByte == -1)");
if (method == "Deserialize")
cw.WriteIndent("break;");
else
cw.WriteIndent("throw new System.IO.EndOfStreamException();");
//Determine if we need the lowID optimization
bool hasLowID = false;
foreach (Field f in m.Fields.Values)
{
if (f.ID < 16)
{
hasLowID = true;
break;
}
}
if (hasLowID)
{
cw.Comment("Optimized reading of known fields with field ID < 16");
cw.Switch("keyByte");
foreach (Field f in m.Fields.Values)
{
if (f.ID >= 16)
continue;
cw.Dedent();
cw.Comment("Field " + f.ID + " " + f.WireType);
cw.Indent();
cw.Case(((f.ID << 3) | (int)f.WireType));
if (FieldSerializer.FieldReader(f, cw))
cw.WriteLine("continue;");
}
cw.SwitchEnd();
cw.WriteLine();
}
cw.WriteLine("var key = global::SilentOrbit.ProtocolBuffers.ProtocolParser.ReadKey((byte)keyByte, stream);");
cw.WriteLine();
cw.Comment("Reading field ID > 16 and unknown field ID/wire type combinations");
cw.Switch("key.Field");
cw.Case(0);
cw.WriteLine("throw new InvalidDataException(\"Invalid field id: 0, something went wrong in the stream\");");
foreach (Field f in m.Fields.Values)
{
if (f.ID < 16)
continue;
cw.Case(f.ID);
//Makes sure we got the right wire type
cw.WriteLine("if(key.WireType != global::SilentOrbit.ProtocolBuffers.Wire." + f.WireType + ")");
cw.WriteIndent("break;"); //This can be changed to throw an exception for unknown formats.
if (FieldSerializer.FieldReader(f, cw))
cw.WriteLine("continue;");
}
cw.CaseDefault();
if (m.OptionPreserveUnknown)
{
cw.WriteLine("if (instance.PreservedFields == null)");
cw.WriteIndent("instance.PreservedFields = new List<global::SilentOrbit.ProtocolBuffers.KeyValue>();");
cw.WriteLine("instance.PreservedFields.Add(new global::SilentOrbit.ProtocolBuffers.KeyValue(key, global::SilentOrbit.ProtocolBuffers.ProtocolParser.ReadValueBytes(stream, key)));");
}
else
{
cw.WriteLine("global::SilentOrbit.ProtocolBuffers.ProtocolParser.SkipKey(stream, key);");
}
cw.WriteLine("break;");
cw.SwitchEnd();
cw.EndBracket();
cw.WriteLine();
if (m.OptionTriggers)
cw.WriteLine("instance.AfterDeserialize();");
cw.WriteLine("return instance;");
cw.EndBracket();
cw.WriteLine();
}
return;
}