当前位置: 首页>>代码示例>>VB.NET>>正文


VB.NET ProcessStartInfo.RedirectStandardOutput属性代码示例

本文整理汇总了VB.NET中System.Diagnostics.ProcessStartInfo.RedirectStandardOutput属性的典型用法代码示例。如果您正苦于以下问题:VB.NET ProcessStartInfo.RedirectStandardOutput属性的具体用法?VB.NET ProcessStartInfo.RedirectStandardOutput怎么用?VB.NET ProcessStartInfo.RedirectStandardOutput使用的例子?那么恭喜您, 这里精选的属性代码示例或许可以为您提供帮助。您也可以进一步了解该属性所在System.Diagnostics.ProcessStartInfo的用法示例。


在下文中一共展示了ProcessStartInfo.RedirectStandardOutput属性的4个代码示例,这些例子默认根据受欢迎程度排序。您可以为喜欢或者感觉有用的代码点赞,您的评价将有助于系统推荐出更棒的VB.NET代码示例。

示例1: Process

' Run "vbc.exe /reference:Microsoft.VisualBasic.dll /out:sample.exe stdstr.vb". UseShellExecute is False 
' because we're specifying an executable directly and in this case depending on it being in a PATH folder. 
' By setting RedirectStandardOutput to True, the output of csc.exe is directed to the Process.StandardOutput 
' stream which is then displayed in this console window directly.    
Using compiler As New Process()
    compiler.StartInfo.FileName = "vbc.exe"
    compiler.StartInfo.Arguments = "/reference:Microsoft.VisualBasic.dll /out:sample.exe stdstr.vb"
    compiler.StartInfo.UseShellExecute = False
    compiler.StartInfo.RedirectStandardOutput = True
    compiler.Start()

    Console.WriteLine(compiler.StandardOutput.ReadToEnd())

    compiler.WaitForExit()
End Using
开发者ID:VB.NET开发者,项目名称:System.Diagnostics,代码行数:15,代码来源:ProcessStartInfo.RedirectStandardOutput

示例2: Main

' 导入命名空间
Imports System.IO

Public Module Example
   Public Sub Main()
      For ctr As Integer = 0 To 499
         Console.WriteLine($"Line {ctr + 1} of 500 written: {ctr + 1/500.0:P2}")
      Next

      Console.Error.WriteLine($"{vbCrLf}Successfully wrote 500 lines.{vbCrLf}")
   End Sub
End Module
开发者ID:VB.NET开发者,项目名称:System.Diagnostics,代码行数:12,代码来源:ProcessStartInfo.RedirectStandardOutput

输出:

The last 50 characters in the output stream are:
49,800.20%
Line 500 of 500 written: 49,900.20%


Error stream: Successfully wrote 500 lines.

示例3: Example

' 导入命名空间
Imports System.Diagnostics'

Public Module Example
   Public Sub Main()
      Dim p As New Process()
      p.StartInfo.UseShellExecute = False  
      p.StartInfo.RedirectStandardOutput = True  
      p.StartInfo.FileName = "Write500Lines.exe"  
      p.Start() 

      ' To avoid deadlocks, always read the output stream first and then wait.  
      Dim output As String = p.StandardOutput.ReadToEnd()  
      p.WaitForExit()

      Console.WriteLine($"The last 50 characters in the output stream are:\n'{output.Substring(output.Length - 50)}'")
   End Sub
End Module
开发者ID:VB.NET开发者,项目名称:System.Diagnostics,代码行数:18,代码来源:ProcessStartInfo.RedirectStandardOutput

输出:

Successfully wrote 500 lines.

The last 50 characters in the output stream are:
49,800.20%
Line 500 of 500 written: 49,900.20%

示例4: Example

' 导入命名空间
Imports System.Diagnostics

Public Module Example
   Public Sub Main()
      Dim p As New Process()  
      p.StartInfo.UseShellExecute = False  
      p.StartInfo.RedirectStandardOutput = True  
      Dim eOut As String = Nothing
      p.StartInfo.RedirectStandardError = True
      AddHandler p.ErrorDataReceived, Sub(sender, e) eOut += e.Data 
      p.StartInfo.FileName = "Write500Lines.exe"  
      p.Start()  

      ' To avoid deadlocks, use an asynchronous read operation on at least one of the streams.  
      p.BeginErrorReadLine()
      Dim output As String = p.StandardOutput.ReadToEnd()  
      p.WaitForExit()

      Console.WriteLine($"The last 50 characters in the output stream are:{vbCrLf}'{output.Substring(output.Length - 50)}'")
      Console.WriteLine($"{vbCrLf}Error stream: {eOut}")
   End Sub
End Module
开发者ID:VB.NET开发者,项目名称:System.Diagnostics,代码行数:23,代码来源:ProcessStartInfo.RedirectStandardOutput

输出:

The last 50 characters in the output stream are:
49,800.20%
Line 500 of 500 written: 49,900.20%


Error stream: Successfully wrote 500 lines.


注:本文中的System.Diagnostics.ProcessStartInfo.RedirectStandardOutput属性示例由纯净天空整理自Github/MSDocs等开源代码及文档管理平台,相关代码片段筛选自各路编程大神贡献的开源项目,源码版权归原作者所有,传播和使用请参考对应项目的License;未经允许,请勿转载。