本文整理汇总了VB.NET中System.ServiceModel.Description.IServiceBehavior接口的典型用法代码示例。如果您正苦于以下问题:VB.NET IServiceBehavior接口的具体用法?VB.NET IServiceBehavior怎么用?VB.NET IServiceBehavior使用的例子?那么, 这里精选的接口代码示例或许可以为您提供帮助。
在下文中一共展示了IServiceBehavior接口的1个代码示例,这些例子默认根据受欢迎程度排序。您可以为喜欢或者感觉有用的代码点赞,您的评价将有助于系统推荐出更棒的VB.NET代码示例。
示例1: AddBindingParameters
' This behavior modifies no binding parameters.
#Region "IServiceBehavior Members"
Public Sub AddBindingParameters(ByVal description As ServiceDescription, ByVal serviceHostBase As ServiceHostBase, ByVal endpoints As System.Collections.ObjectModel.Collection(Of ServiceEndpoint), ByVal parameters As System.ServiceModel.Channels.BindingParameterCollection) Implements IServiceBehavior.AddBindingParameters
Return
End Sub
' This behavior is an IErrorHandler implementation and
' must be applied to each ChannelDispatcher.
Public Sub ApplyDispatchBehavior(ByVal description As ServiceDescription, ByVal serviceHostBase As ServiceHostBase) Implements IServiceBehavior.ApplyDispatchBehavior
Console.WriteLine("The EnforceGreetingFaultBehavior has been applied.")
For Each chanDisp As ChannelDispatcher In serviceHostBase.ChannelDispatchers
chanDisp.ErrorHandlers.Add(Me)
Next chanDisp
End Sub
' This behavior requires that the contract have a SOAP fault with a detail type of GreetingFault.
Public Sub Validate(ByVal description As ServiceDescription, ByVal serviceHostBase As ServiceHostBase) Implements IServiceBehavior.Validate
Console.WriteLine("Validate is called.")
For Each se As ServiceEndpoint In description.Endpoints
' Must not examine any metadata endpoint.
If se.Contract.Name.Equals("IMetadataExchange") AndAlso se.Contract.Namespace.Equals("http://schemas.microsoft.com/2006/04/mex") Then
Continue For
End If
For Each opDesc As OperationDescription In se.Contract.Operations
If opDesc.Faults.Count = 0 Then
Throw New InvalidOperationException(String.Format("EnforceGreetingFaultBehavior requires a " & "FaultContractAttribute(typeof(GreetingFault)) in each operation contract. " & "The ""{0}"" operation contains no FaultContractAttribute.", opDesc.Name))
End If
Dim gfExists As Boolean = False
For Each fault As FaultDescription In opDesc.Faults
If fault.DetailType.Equals(GetType(GreetingFault)) Then
gfExists = True
Continue For
End If
Next fault
If gfExists = False Then
Throw New InvalidOperationException("EnforceGreetingFaultBehavior requires a FaultContractAttribute(typeof(GreetingFault)) in an operation contract.")
End If
Next opDesc
Next se
End Sub
#End Region