本文整理汇总了Python中mpf.system.utility_functions.Util.int_to_hex_string方法的典型用法代码示例。如果您正苦于以下问题:Python Util.int_to_hex_string方法的具体用法?Python Util.int_to_hex_string怎么用?Python Util.int_to_hex_string使用的例子?那么恭喜您, 这里精选的方法代码示例或许可以为您提供帮助。您也可以进一步了解该方法所在类mpf.system.utility_functions.Util
的用法示例。
在下文中一共展示了Util.int_to_hex_string方法的9个代码示例,这些例子默认根据受欢迎程度排序。您可以为喜欢或者感觉有用的代码点赞,您的评价将有助于系统推荐出更棒的Python代码示例。
示例1: receive_sa
# 需要导入模块: from mpf.system.utility_functions import Util [as 别名]
# 或者: from mpf.system.utility_functions.Util import int_to_hex_string [as 别名]
def receive_sa(self, msg):
self.log.info("Received SA: %s", msg)
hw_states = dict()
num_local, local_states, num_nw, nw_states = msg.split(',')
for offset, byte in enumerate(bytearray.fromhex(nw_states)):
for i in range(8):
num = Util.int_to_hex_string((offset * 8) + i)
if byte & (2**i):
hw_states[(num, 1)] = 1
else:
hw_states[(num, 1)] = 0
for offset, byte in enumerate(bytearray.fromhex(local_states)):
for i in range(8):
num = Util.int_to_hex_string((offset * 8) + i)
if byte & (2**i):
hw_states[(num, 0)] = 1
else:
hw_states[(num, 0)] = 0
self.hw_switch_data = hw_states
示例2: pulse
# 需要导入模块: from mpf.system.utility_functions import Util [as 别名]
# 或者: from mpf.system.utility_functions.Util import int_to_hex_string [as 别名]
def pulse(self, milliseconds=None):
"""Pulses this driver. """
if not milliseconds:
hex_ms_string = self.driver_settings['pulse_ms']
else:
hex_ms_string = Util.int_to_hex_string(milliseconds)
if self.autofire:
cmd = (self.driver_settings['trigger_cmd'] +
self.driver_settings['number'] + ',' +
'01')
if milliseconds:
self.log.debug("Received command to pulse driver for %sms, but"
"this driver is configured with an autofire rule"
", so that pulse value will be used instead.")
else:
cmd = (self.driver_settings['config_cmd'] +
self.driver_settings['number'] +
',89,00,10,' +
hex_ms_string + ',' +
self.driver_settings['pwm1'] + ',00,00,' +
self.driver_settings['recycle_ms'])
self.log.debug("Sending Pulse Command: %s", cmd)
self.send(cmd)
self.check_auto()
示例3: configure_led
# 需要导入模块: from mpf.system.utility_functions import Util [as 别名]
# 或者: from mpf.system.utility_functions.Util import int_to_hex_string [as 别名]
def configure_led(self, config):
if not self.rgb_connection:
self.log.critical("A request was made to configure a FAST LED, "
"but no connection to an LED processor is "
"available")
sys.exit()
if not self.flag_led_tick_registered:
self.machine.events.add_handler('timer_tick', self.update_leds)
self.flag_led_tick_registered = True
# if the LED number is in <channel> - <led> format, convert it to a
# FAST hardware number
if '-' in config['number_str']:
num = config['number_str'].split('-')
config['number'] = (int(num[0]) * 64) + int(num[1])
self.config['config_number_format'] = 'int'
else:
config['number'] = str(config['number'])
if self.config['config_number_format'] == 'int':
config['number'] = Util.int_to_hex_string(config['number'])
else:
config['number'] = Util.normalize_hex_string(config['number'])
this_fast_led = FASTDirectLED(config['number'])
self.fast_leds.add(this_fast_led)
return this_fast_led
示例4: create_driver_settings
# 需要导入模块: from mpf.system.utility_functions import Util [as 别名]
# 或者: from mpf.system.utility_functions.Util import int_to_hex_string [as 别名]
def create_driver_settings(self, machine, pulse_ms=None, **kwargs):
return_dict = dict()
if pulse_ms is None:
pulse_ms = machine.config['mpf']['default_pulse_ms']
return_dict['pulse_ms'] = Util.int_to_hex_string(pulse_ms)
return_dict['pwm1'] = 'ff'
return_dict['pwm2'] = 'ff'
return_dict['recycle_ms'] = '00'
return return_dict
示例5: configure_matrixlight
# 需要导入模块: from mpf.system.utility_functions import Util [as 别名]
# 或者: from mpf.system.utility_functions.Util import int_to_hex_string [as 别名]
def configure_matrixlight(self, config):
if not self.net_connection:
self.log.critical("A request was made to configure a FAST matrix "
"light, but no connection to a NET processor is "
"available")
sys.exit()
if self.machine_type == 'wpc': # translate number to FAST light num
config['number'] = self.wpc_light_map.get(
config['number_str'].upper())
elif self.config['config_number_format'] == 'int':
config['number'] = Util.int_to_hex_string(config['number'])
else:
config['number'] = Util.normalize_hex_string(config['number'])
return (FASTMatrixLight(config['number'], self.net_connection.send),
config['number'])
示例6: configure_driver
# 需要导入模块: from mpf.system.utility_functions import Util [as 别名]
# 或者: from mpf.system.utility_functions.Util import int_to_hex_string [as 别名]
def configure_driver(self, config, device_type='coil'):
if not self.net_connection:
self.log.critical("A request was made to configure a FAST driver, "
"but no connection to a NET processor is "
"available")
sys.exit()
# If we have WPC driver boards, look up the driver number
if self.machine_type == 'wpc':
config['number'] = self.wpc_driver_map.get(
config['number_str'].upper())
if ('connection' in config and
config['connection'].lower() == 'network'):
config['connection'] = 1
else:
config['connection'] = 0 # local driver (default for WPC)
# If we have FAST IO boards, we need to make sure we have hex strings
elif self.machine_type == 'fast':
if self.config['config_number_format'] == 'int':
config['number'] = Util.int_to_hex_string(config['number'])
else:
config['number'] = Util.normalize_hex_string(config['number'])
# Now figure out the connection type
if ('connection' in config and
config['connection'].lower() == 'local'):
config['connection'] = 0
else:
config['connection'] = 1 # network driver (default for FAST)
else:
self.log.critical("Invalid machine type: {0{}}".format(
self.machine_type))
sys.exit()
return (FASTDriver(config, self.net_connection.send, self.machine),
(config['number'], config['connection']))
示例7: merge_driver_settings
# 需要导入模块: from mpf.system.utility_functions import Util [as 别名]
# 或者: from mpf.system.utility_functions.Util import int_to_hex_string [as 别名]
def merge_driver_settings(self,
pulse_ms=None,
pwm_on_ms=None,
pwm_off_ms=None,
pulse_power=None,
hold_power=None,
pulse_power32=None,
hold_power32=None,
pulse_pwm_mask=None,
hold_pwm_mask=None,
recycle_ms=None,
activation_time=None,
**kwargs
):
if pwm_on_ms:
raise ValueError("The setting 'pwm_on_ms' is not valid with the "
"FAST platform. Use a hold_power or hold_pwm_mask"
" instead.")
if pwm_off_ms:
raise ValueError("The setting 'pwm_off_ms' is not valid with the "
"FAST platform. Use a hold_power or hold_pwm_mask"
" instead.")
if pulse_power32:
raise NotImplementedError('"pulse_power32" has not been '
'implemented yet')
if hold_power32:
raise NotImplementedError('"hold_power32" has not been '
'implemented yet')
return_dict = dict()
return_dict['pwm32'] = None
if activation_time is not None:
if activation_time > 25500:
raise ValueError('Max FAST timed_hold time is 25.5s')
# FAST activation times are ms * 100
return_dict['activation_time'] = str(activation_time / 100)
if recycle_ms is not None:
return_dict['recycle_ms'] = (Util.int_to_hex_string(recycle_ms))
if pulse_ms is not None:
return_dict['pulse_ms'] = Util.int_to_hex_string(pulse_ms)
if pulse_pwm_mask:
pulse_pwm_mask = str(pulse_pwm_mask)
if len(pulse_pwm_mask) == 32:
return_dict['pwm1'] = Util.bin_str_to_hex_str(pulse_pwm_mask, 8)
elif len(pulse_pwm_mask) == 8:
return_dict['pwm1'] = Util.bin_str_to_hex_str(pulse_pwm_mask, 2)
else:
raise ValueError("pulse_pwm_mask must either be 8 or 32 bits")
elif pulse_power32 is not None:
return_dict['pwm32'] = Util.pwm32_to_hex_string(pulse_power32)
elif pulse_power is not None:
return_dict['pwm1'] = Util.pwm8_to_hex_string(pulse_power)
if hold_pwm_mask:
hold_pwm_mask = str(hold_pwm_mask)
if len(hold_pwm_mask) == 32:
return_dict['pwm2'] = Util.bin_str_to_hex_str(hold_pwm_mask, 8)
elif len(hold_pwm_mask) == 8:
return_dict['pwm2'] = Util.bin_str_to_hex_str(hold_pwm_mask, 2)
else:
raise ValueError("hold_pwm_mask must either be 8 or 32 bits")
elif hold_power32 is not None:
return_dict['pwm32'] = Util.pwm32_to_hex_string(hold_power32)
elif hold_power is not None:
return_dict['pwm2'] = Util.pwm8_to_hex_string(hold_power)
return return_dict
示例8: write_hw_rule
# 需要导入模块: from mpf.system.utility_functions import Util [as 别名]
# 或者: from mpf.system.utility_functions.Util import int_to_hex_string [as 别名]
def write_hw_rule(self, switch_obj, sw_activity, driver_obj, driver_action,
disable_on_release=True, drive_now=False,
**driver_settings_overrides):
"""Used to write (or update) a hardware rule to the FAST controller.
*Hardware Rules* are used to configure the hardware controller to
automatically change driver states based on switch changes. These rules
are completely handled by the hardware (i.e. with no interaction from
the Python game code). They're used for things that you want to happen
fast, like firing coils when flipper buttons are pushed, slingshots, pop
bumpers, etc.
You can overwrite existing hardware rules at any time to change or
remove them.
Args:
switch_obj: Which switch you're creating this rule for. The
parameter is a reference to the switch object itself.
sw_activity: Int which specifies whether this coil should fire when
the switch becomes active (1) or inactive (0)
driver_obj: Driver object this rule is being set for.
driver_action: String 'pulse' or 'hold' which describe what action
will be applied to this driver
drive_now: Should the hardware check the state of the switches when
this rule is first applied, and fire the coils if they should
be? Typically this is True, especially with flippers because you
want them to fire if the player is holding in the buttons when
the machine enables the flippers (which is done via several
calls to this method.)
"""
driver_settings = deepcopy(driver_obj.hw_driver.driver_settings)
driver_settings.update(driver_obj.hw_driver.merge_driver_settings(
**driver_settings_overrides))
self.log.debug("Setting HW Rule. Switch: %s, Switch_action: %s, Driver:"
" %s, Driver settings: %s", switch_obj.name, sw_activity,
driver_obj.name, driver_settings)
control = 0x01 # Driver enabled
if drive_now:
control += 0x08
if sw_activity == 0:
control += 0x10
control = Util.int_to_hex_string(int(control))
# todo need to implement disable_on_release
if driver_action == 'pulse':
mode = '10' # Mode 10 settings
param1 = driver_settings['pulse_ms'] # initial pulse ms
param2 = driver_settings['pwm1'] # intial pwm
param3 = '00' # pulse 2 time
param4 = '00' # pulse 2 pwm
param5 = driver_settings['recycle_ms'] # recycle ms
elif driver_action == 'hold':
mode = '18' # Mode 18 settings
param1 = driver_settings['pulse_ms'] # intiial pulse ms
param2 = driver_settings['pwm1'] # intial pwm
param3 = driver_settings['pwm2'] # hold pwm
param4 = driver_settings['recycle_ms'] # recycle ms
param5 = '00' # not used with Mode 18
elif driver_action == 'timed_hold':
# fast hold time is ms*100
hold_value = driver_settings['activation_time']
mode = '70' # Mode 70 settings
param1 = driver_settings['pulse_ms'] # intiial pulse ms
param2 = driver_settings['pwm1'] # intial pwm
param3 = hold_value # hold time
param4 = driver_settings['pwm2'] # hold pwm
param5 = driver_settings['recycle_ms'] # recycle ms
else:
raise ValueError("Invalid driver action: '%s'. Expected 'hold', "
"'timed_hold', or 'pulse'" % (driver_action))
self.hw_rules[driver_obj] = {'mode': mode,
'param1': param1,
'param2': param2,
'param3': param3,
'param4': param4,
'param5': param5,
'switch': switch_obj.number}
cmd = (driver_settings['config_cmd'] +
driver_obj.number[0] + ',' +
control + ',' +
switch_obj.number[0] + ',' +
mode + ',' +
param1 + ',' +
param2 + ',' +
param3 + ',' +
#.........这里部分代码省略.........
示例9: configure_switch
# 需要导入模块: from mpf.system.utility_functions import Util [as 别名]
# 或者: from mpf.system.utility_functions.Util import int_to_hex_string [as 别名]
def configure_switch(self, config):
"""Configures the switch object for a FAST Pinball controller.
FAST Controllers support two types of switches: `local` and `network`.
Local switches are switches that are connected to the FAST controller
board itself, and network switches are those connected to a FAST I/O
board.
MPF needs to know which type of switch is this is. You can specify the
switch's connection type in the config file via the ``connection:``
setting (either ``local`` or ``network``).
If a connection type is not specified, this method will use some
intelligence to try to figure out which default should be used.
If the DriverBoard type is ``fast``, then it assumes the default is
``network``. If it's anything else (``wpc``, ``system11``, ``bally``,
etc.) then it assumes the connection type is ``local``. Connection types
can be mixed and matched in the same machine.
"""
if not self.net_connection:
self.log.critical("A request was made to configure a FAST switch, "
"but no connection to a NET processor is "
"available")
sys.exit()
if self.machine_type == 'wpc': # translate switch number to FAST switch
config['number'] = self.wpc_switch_map.get(
config['number_str'].upper())
if 'connection' not in config:
config['connection'] = 0 # local switch (default for WPC)
else:
config['connection'] = 1 # network switch
elif self.machine_type == 'fast':
if 'connection' not in config:
config['connection'] = 1 # network switch (default for FAST)
else:
config['connection'] = 0 # local switch
if self.config['config_number_format'] == 'int':
config['number'] = Util.int_to_hex_string(config['number'])
else:
config['number'] = Util.normalize_hex_string(config['number'])
# convert the switch number into a tuple which is:
# (switch number, connection)
config['number'] = (config['number'], config['connection'])
if not config['debounce_open']:
config['debounce_open'] = self.config['default_debounce_open']
if not config['debounce_close']:
config['debounce_close'] = self.config['default_debounce_close']
self.log.debug("FAST Switch hardware tuple: %s", config['number'])
switch = FASTSwitch(number=config['number'],
debounce_open=config['debounce_open'],
debounce_close=config['debounce_close'],
sender=self.net_connection.send)
return switch, config['number']