示例1: main

def main():
    """ Main function """
    devices = ['M11200362H', 'M11200362C', 'M11200362A',
               'M11200362E', 'M11200362D', 'M11210022B', 'M11200362G']
    ranges = {}
    ranges['M11200362H'] = 2.5 # Pressure controller
    ranges['M11200362C'] = 10 # Flow1
    ranges['M11200362A'] = 10 # Flow2
    ranges['M11200362E'] = 5 # Flow3
    ranges['M11200362D'] = 5 # Flow4
    ranges['M11210022B'] = 10 # Flow5 (NH3 compatible)
    ranges['M11200362G'] = 1 # Flow6

    flow_control = FlowControl(devices=devices, ranges=ranges,
                               socket_name='microreactorNG_mfc_control')
    flow_control.start()

    logger = ValueLogger(flow_control, comp_val=1, comp_type='log', low_comp=0.0001)
    logger.start()

    db_logger = ContinuousDataSaver(continuous_data_table='dateplots_microreactorNG',
                                    username=credentials.user,
                                    password=credentials.passwd,
                                    measurement_codenames=['microreactorng_pressure_reactor'])
    db_logger.start()

    time.sleep(5)
    while True:
        time.sleep(0.25)
        value = logger.read_value()
        if logger.read_trigged():
            print(value)
            db_logger.save_point_now('microreactorng_pressure_reactor', value)
            logger.clear_trigged()
开发者ID:CINF,项目名称:PyExpLabSys,代码行数:34,代码来源:socket_server.py

示例2: main

def main():
    """ Main function """
    code_names = ['pvd309_temp_dca_cell', 'pvd309_temp_mai_cell']

    reader = TemperatureReader()
    reader.start()
    
    loggers = {}
    loggers[code_names[0]] = ValueLogger(reader, channel=1, comp_val = 0.5, comp_type = 'lin')
    loggers[code_names[0]].start()
    loggers[code_names[1]] = ValueLogger(reader, channel=2, comp_val = 0.5, comp_type = 'lin')
    loggers[code_names[1]].start()

    datasocket = DateDataPullSocket('pvd_309_temp', code_names, timeouts=[2.0] * 2, port=9001)
    datasocket.start()
    livesocket = LiveSocket('pvd_309_temperatures', code_names)
    livesocket.start()

    db_logger = ContinuousDataSaver(continuous_data_table='dateplots_pvd309',
                                    username=credentials.user,
                                    password=credentials.passwd,
                                    measurement_codenames=code_names)
    db_logger.start()
    time.sleep(5)
    while not reader.quit:
        time.sleep(0.25)
        for name in code_names:
            print(reader.ttl)
            value = loggers[name].read_value()
            datasocket.set_point_now(name, value)
            livesocket.set_point_now(name, value)
            if loggers[name].read_trigged():
                print(name + ': ' + str(value))
                db_logger.save_point_now(name, value)
                loggers[name].clear_trigged()
开发者ID:CINF,项目名称:PyExpLabSys,代码行数:35,代码来源:datalogger.py

示例3: main

def main():
    """Main function"""
    pvci = PVCi('/dev/serial/by-id/'
                'usb-FTDI_USB-RS485_Cable_FTY3M2GN-if00-port0')

    # Start live socket
    live_socket = LiveSocket('thetaprobe_pvci', list(CODENAME_TRANSLATION.keys()),
                             sane_interval=0.5)
    live_socket.start()

    # Start database saver
    database_saver = ContinuousDataSaver(
        'dateplots_thetaprobe', credentials.USERNAME,
        credentials.PASSWORD, list(CODENAME_TRANSLATION.keys())
    )
    database_saver.start()

    # Set up criterium checker
    criterium_checker = LoggingCriteriumChecker(
        codenames=list(CODENAME_TRANSLATION.keys()),
        types=['log', 'log', 'lin'],
        criteria=[0.1, 0.1, 1.0],
    )


    try:
        run(pvci, live_socket, database_saver, criterium_checker)
    except KeyboardInterrupt:
        pvci.close()
        live_socket.stop()
        database_saver.stop()
开发者ID:jlopezBolt,项目名称:PyExpLabSys,代码行数:31,代码来源:pvci_monitor.py

示例4: main

def main():
    """ Main function """

    codenames = ['sniffer_inlet_gas_pressure']
    mfc = AnalogMFC(1, 10, 5)
    mfcs = {}
    mfcs[codenames[0]] = mfc

    flow_control = FlowControl(mfcs, 'sniffer')
    flow_control.start()

    loggers = {}
    loggers[codenames[0]] = ValueLogger(flow_control, comp_val=0.02, comp_type='lin',
                                        low_comp=0.01, channel=codenames[0])
    loggers[codenames[0]].start()
    
    db_logger = ContinuousDataSaver(continuous_data_table='dateplots_sniffer',
                                    username=credentials.user,
                                    password=credentials.passwd,
                                    measurement_codenames=codenames)
    db_logger.start()

    while True:
        time.sleep(0.5)
        for name in codenames:
            if loggers[name].read_trigged():
                print(name + ': ' + str(loggers[name].value))
                db_logger.save_point_now(name, loggers[name].value)
                loggers[name].clear_trigged()
开发者ID:CINF,项目名称:PyExpLabSys,代码行数:29,代码来源:analog_mfc.py

示例5: main

def main():
    """ Main function """
    tempreader = TemperatureReader()
    tempreader.daemon = True
    tempreader.start()

    temp_logger = ValueLogger(tempreader, comp_val=1)
    temp_logger.start()

    db_logger = ContinuousDataSaver(continuous_data_table='dateplots_chemlab307',
                                    username=credentials.user,
                                    password=credentials.passwd,
                                    measurement_codenames=['chemlab307_muffle_furnace'])

    socket = DateDataPullSocket('muffle_furnace',
                                ['chemlab307_muffle_furnace'],
                                timeouts=[1.0])
    socket.start()

    livesocket = LiveSocket('muffle_furnace', ['chemlab307_muffle_furnace'])
    livesocket.start()

    db_logger.start()
    time.sleep(5)
    while True:
        time.sleep(0.25)
        value = temp_logger.read_value()
        socket.set_point_now('chemlab307_muffle_furnace', value)
        livesocket.set_point_now('chemlab307_muffle_furnace', value)
        if temp_logger.read_trigged():
            print(value)
            db_logger.save_point_now('chemlab307_muffle_furnace', value)
            temp_logger.clear_trigged()
开发者ID:CINF,项目名称:PyExpLabSys,代码行数:33,代码来源:data_logger.py

示例6: main

def main():
    """ Main loop """
    mainpump = tp.TurboDriver(adress=1, port=settings.port)
    mainpump.start()

    tui = tp.CursesTui(mainpump)
    tui.daemon = True
    tui.start()

    reader = tp.TurboReader(mainpump)
    reader.daemon = True
    reader.start()

    time.sleep(10) # Allow reader to make meaningfull moving avarage

    codenames = [settings.table_prefix + '_turbo_speed',
                 settings.table_prefix + '_turbo_power',
                 settings.table_prefix + '_turbo_current',
                 settings.table_prefix + '_turbo_temp_motor',
                 settings.table_prefix + '_turbo_temp_bottom',
                 settings.table_prefix + '_turbo_temp_bearings',
                 settings.table_prefix + '_turbo_temp_electronics']
    loggers = {}

    loggers[codenames[0]] = tp.TurboLogger(reader, 'rotation_speed', maximumtime=600)
    loggers[codenames[1]] = tp.TurboLogger(reader, 'drive_power', maximumtime=600)
    loggers[codenames[2]] = tp.TurboLogger(reader, 'drive_current', maximumtime=600)
    loggers[codenames[3]] = tp.TurboLogger(reader, 'temp_motor', maximumtime=600)
    loggers[codenames[4]] = tp.TurboLogger(reader, 'temp_bottom', maximumtime=600)
    loggers[codenames[5]] = tp.TurboLogger(reader, 'temp_bearings', maximumtime=600)
    loggers[codenames[6]] = tp.TurboLogger(reader, 'temp_electronics', maximumtime=600)

    for name in codenames:
        loggers[name].daemon = True
        loggers[name].start()

    livesocket = LiveSocket(settings.name + '-turboreader', codenames)
    livesocket.start()

    socket = DateDataPullSocket(settings.name + '-turboreader', codenames,
                                timeouts=[1.0] * len(codenames), port=9000)
    socket.start()

    db_logger = ContinuousDataSaver(continuous_data_table=settings.table,
                                    username=settings.user,
                                    password=settings.passwd,
                                    measurement_codenames=codenames)
    db_logger.start()
    time.sleep(5)

    while mainpump.running:
        time.sleep(0.1)
        for name in codenames:
            value = loggers[name].read_value()
            socket.set_point_now(name, value) # Notice, this is the averaged value
            livesocket.set_point_now(name, value) # Notice, this is the averaged value
            if loggers[name].trigged:
                db_logger.save_point_now(name, value)
                loggers[name].trigged = False
开发者ID:CINF,项目名称:PyExpLabSys,代码行数:59,代码来源:turbo_logger.py

示例7: main

def main():
    """ Main function """
    pumpreaders = {}
    loggers = {}
    channels = ['temperature', 'controller_temperature', 'run_hours', 'rotational_speed',
                'controller_run_hours', 'time_to_service']
    codenames = []
    for port, codename in settings.channels.items():
        pumpreaders[port] = PumpReader(port)
        pumpreaders[port].daemon = True
        pumpreaders[port].start()
        pumpreaders[port].loggers = {}

        for channel in channels:
            codenames.append(codename + '_' + channel) # Build the list of codenames
            loggers[port + channel] = ValueLogger(pumpreaders[port], comp_val=0.9,
                                                  channel=channel, maximumtime=600)
            loggers[port + channel].start()

    #socket = DateDataPullSocket('Pump Reader', codenames, timeouts=2.0)
    #socket.start()
    #live_socket = LiveSocket('Pump Reader',  codenames)
    #live_socket.start()

    db_logger = ContinuousDataSaver(continuous_data_table=settings.table,
                                    username=credentials.user,
                                    password=credentials.passwd,
                                    measurement_codenames=codenames) # Codename list created
                                                                     # along with loggers
    db_logger.start()

    time.sleep(10)

    alive = True
    while alive:
        for port, base_codename in settings.channels.items():
            time.sleep(10)
            for channel in channels:
                if loggers[port + channel].is_alive is False:
                    alive = False

                codename = base_codename + '_' + channel
                value = loggers[port + channel].read_value()
                #socket.set_point_now(codename, value)
                #live_socket.set_point_now(codename, value)
                if loggers[port + channel].read_trigged():
                    print(port + channel + ': ' + str(value))
                    db_logger.save_point_now(codename, value)
                    loggers[port + channel].clear_trigged()
开发者ID:CINF,项目名称:PyExpLabSys,代码行数:49,代码来源:edwards_nxds_logger.py

示例8: main

def main():
    """ Main function """
    ups = galaxy_3500.Galaxy3500('b312-ups')
    reader = UpsReader(ups)
    reader.daemon = True
    reader.start()

    time.sleep(5)

    codenames = ['b312_ups_temperature', 'b312_ups_kVAPh1', 'b312_ups_kVAPh2',
                 'b312_ups_kVAPh3', 'b312_ups_output_current_Ph1',
                 'b312_ups_output_current_Ph2', 'b312_ups_output_current_Ph3',
                 'b312_ups_input_frequency', 'b312_ups_input_voltage_Ph1',
                 'b312_ups_input_voltage_Ph2', 'b312_ups_input_voltage_Ph3',
                 'b312_ups_output_voltage_Ph1', 'b312_ups_output_voltage_Ph2',
                 'b312_ups_output_voltage_Ph3', 'b312_ups_battery_voltage',
                 'b312_ups_battery_current', 'b312_ups_battery_state_of_charge',
                 'b312_ups_output_frequency']

    loggers = {}
    for i in range(0, len(codenames)):
        loggers[codenames[i]] = ValueLogger(reader, comp_val=0.1, channel=i)
        loggers[codenames[i]].start()
    socket = DateDataPullSocket('UPS status', codenames,
                                timeouts=[5.0] * len(codenames))
    socket.start()

    live_socket = LiveSocket('UPS Status', codenames)
    live_socket.start()

    db_logger = ContinuousDataSaver(continuous_data_table='dateplots_ups_b312',
                                    username=credentials.user,
                                    password=credentials.passwd,
                                    measurement_codenames=codenames)
    db_logger.start()

    time.sleep(5)

    while reader.isAlive():
        time.sleep(0.25)
        for name in codenames:
            value = loggers[name].read_value()
            socket.set_point_now(name, value)
            live_socket.set_point_now(name, value)
            if loggers[name].read_trigged():
                print(value)
                db_logger.save_point_now(name, value)
                loggers[name].clear_trigged()
开发者ID:CINF,项目名称:PyExpLabSys,代码行数:48,代码来源:ups_logger.py

示例9: main

def main():
    """ Main function """
    logging.basicConfig(filename="logger.txt", level=logging.ERROR)
    logging.basicConfig(level=logging.ERROR)

    qcm_port = ('/dev/serial/by-id/' +
                'usb-Prolific_Technology_Inc._USB-Serial_Controller-if00-port0')
    qcm = inficon.InficonSQM160(qcm_port)
    reader = QcmReader(qcm)
    reader.daemon = True
    reader.start()

    codenames = ['volvo_qcm_frequency',
                 'volvo_qcm_crystal_life',
                 'volvo_qcm_thickness']
    loggers = {}
    loggers[codenames[0]] = ValueLogger(reader, comp_val=0.1, channel=0)
    loggers[codenames[0]].start()
    loggers[codenames[1]] = ValueLogger(reader, comp_val=0.01, channel=1)
    loggers[codenames[1]].start()
    loggers[codenames[2]] = ValueLogger(reader, comp_val=0.001, channel=2)
    loggers[codenames[2]].start()
    socket = DateDataPullSocket('Volvo QCM', codenames, port=9000,
                                timeouts=[5.0] * len(codenames))
    socket.start()

    livesocket = LiveSocket('Volvo data logger', codenames)
    livesocket.start()

    db_logger = ContinuousDataSaver(continuous_data_table='dateplots_volvo',
                                    username=credentials.user,
                                    password=credentials.passwd,
                                    measurement_codenames=codenames)
    db_logger.start()

    time.sleep(5)

    while reader.isAlive():
        time.sleep(0.25)
        for name in codenames:
            value = loggers[name].read_value()
            socket.set_point_now(name, value)
            livesocket.set_point_now(name, value)
            if loggers[name].read_trigged():
                print(value)
                db_logger.save_point_now(name, value)
                loggers[name].clear_trigged()
开发者ID:CINF,项目名称:PyExpLabSys,代码行数:47,代码来源:qcm_logger.py

示例10: main

def main():
    """Main function"""
    chiller_port = '/dev/serial/by-id/'
    chiller_port += 'usb-1a86_USB2.0-Ser_-if00-port0'

    LOG.info('Using chiller port %s', chiller_port)
    reader = ChillerReader(chiller_port)
    reader.start()
    LOG.info('ChillerReader started')

    codenames = ['uhv_sputterchamber_chiller_temperature',
                 'uhv_sputterchamber_chiller_flow',
                 'uhv_sputterchamber_chiller_temperature_ambient',
                 'uhv_sputterchamber_chiller_pressure',
                 'uhv_sputterchamber_chiller_temperature_setpoint']
    LOG.debug('Using codenames %s', codenames)
    loggers = {}
    for i in range(0, len(codenames)):
        loggers[codenames[i]] = ValueLogger(reader, comp_val=0.11, channel=i)
        loggers[codenames[i]].start()

    live_socket_name = 'uhv_sputterchamber'
    live_socket = LiveSocket(live_socket_name, codenames)
    live_socket.start()
    LOG.info('Live socket init and started with name "%s"', live_socket_name)

    db_table = 'dateplots_uhv_sputterchamber'
    db_logger = ContinuousDataSaver(continuous_data_table=db_table,
                                    username=credentials.user,
                                    password=credentials.passwd,
                                    measurement_codenames=codenames)
    db_logger.start()
    LOG.info('ContinuousLogger init and started on table "%s"', db_table)

    time.sleep(5)

    while reader.isAlive():
        time.sleep(0.25)
        for name in codenames:
            value = loggers[name].read_value()
            if not math.isnan(value):
                live_socket.set_point_now(name, value)
                if loggers[name].read_trigged():
                    LOG.debug('Log value %s for codename "%s"', value, name)
                    db_logger.save_point_now(name, value)
                    loggers[name].clear_trigged()
开发者ID:CINF,项目名称:PyExpLabSys,代码行数:46,代码来源:chiller_logger.py

示例11: main

def main():
    """ Main function """

    codenames = []
    for channel in settings.channels.values():
        channel['reader'] = SocketReaderClass(channel['host'], channel['port'],
                                              channel['command'])
        channel['reader'].start()
        channel['logger'] = ValueLogger(channel['reader'], comp_val=channel['comp_value'])
        channel['logger'].daemon = True
        channel['logger'].start()
        codenames.append(channel['codename'])

    try:
        port = settings.port_number
    except AttributeError:
        port = 9000
    pullsocket = DateDataPullSocket(settings.user + '-socket_logger',
                                    codenames, timeouts=5, port=port)
    pullsocket.start()

        
    db_logger = ContinuousDataSaver(continuous_data_table=settings.dateplot_table,
                                    username=settings.user,
                                    password=settings.passwd,
                                    measurement_codenames=codenames)
    db_logger.start()

    time.sleep(2)

    everything_ok = True
    while everything_ok:
        time.sleep(0.25)
        for channel in settings.channels.values():
            if not channel['reader'].isAlive():
                everything_ok = False
                # Report error here!!!
                # Consider to keep program running even in case of
                # socket failures
            value = channel['logger'].read_value()
            pullsocket.set_point_now(channel['codename'], value)
            if channel['logger'].read_trigged():
                print(value)
                db_logger.save_point_now(channel['codename'], value)
                channel['logger'].clear_trigged()
开发者ID:CINF,项目名称:PyExpLabSys,代码行数:45,代码来源:socket_logger.py

示例12: main

def main():
    """ Main function """
    logging.basicConfig(filename="logger.txt", level=logging.ERROR)
    logging.basicConfig(level=logging.ERROR)

    port = '/dev/serial/by-id/usb-Prolific_Technology_Inc._USB-Serial_Controller_D-if00-port'
    port = '/dev/ttyUSB0'
    codenames = ['xrd_pressure_turbo_gas_system', 'xrd_pressure_gas_system_wrg',
                 'xrd_pressure_mass_spec_wrg', 'xrd_pressure_gas_system_baratron']
    reader = PressureReader(port)
    reader.daemon = True
    reader.start()

    loggers = {}
    loggers[codenames[0]] = ValueLogger(reader, comp_val=0.02, comp_type='log', channel=1)
    loggers[codenames[1]] = ValueLogger(reader, comp_val=0.02, comp_type='log', channel=2)
    loggers[codenames[2]] = ValueLogger(reader, comp_val=0.02, comp_type='log', channel=3)
    loggers[codenames[3]] = ValueLogger(reader, comp_val=2, comp_type='lin', channel=4)

    for i in range(0, 4):
        loggers[codenames[i]].start()

    socket = DateDataPullSocket('XRD Pressure', codenames, timeouts=[2.0] * len(codenames))
    socket.start()
    live_socket = LiveSocket('XRD pressure', codenames, 2)
    live_socket.start()

    db_logger = ContinuousDataSaver(continuous_data_table='dateplots_xrd',
                                    username=credentials.user,
                                    password=credentials.passwd,
                                    measurement_codenames=codenames)
    db_logger.start()

    time.sleep(5)
    while True:
        time.sleep(0.25)
        for name in codenames:
            value = loggers[name].read_value()
            socket.set_point_now(name, value)
            live_socket.set_point_now(name, value)
            if loggers[name].read_trigged():
                print(name + ': ' + str(value))
                db_logger.save_point_now(name, value)
                loggers[name].clear_trigged()
开发者ID:jlopezBolt,项目名称:PyExpLabSys,代码行数:44,代码来源:data_logger.py

示例13: main

def main():
    """ Main function """
    logging.basicConfig(filename="logger.txt", level=logging.ERROR)
    logging.basicConfig(level=logging.ERROR)

    i2c_helper = ABEHelpers()
    bus = i2c_helper.get_smbus()
    adc_instance = DeltaSigma(bus, 0x68, 0x69, 18)

    tempreader = TemperatureReader(adc_instance)
    tempreader.daemon = True
    tempreader.start()

    codenames = ["cooling_water_hot", "cooling_water_cold"]
    loggers = {}
    for i in range(0, 2):
        loggers[codenames[i]] = ValueLogger(tempreader, comp_val=0.5, channel=i)
        loggers[codenames[i]].start()
    socket = DateDataPullSocket("hall_cooling_water_temp", codenames, timeouts=2.0)
    socket.start()

    live_socket = LiveSocket("hall_waterpressure", codenames)
    live_socket.start()

    db_logger = ContinuousDataSaver(
        continuous_data_table="dateplots_hall",
        username=credentials.user,
        password=credentials.passwd,
        measurement_codenames=codenames,
    )
    db_logger.start()

    time.sleep(5)

    while tempreader.is_alive():
        time.sleep(0.25)
        for name in codenames:
            value = loggers[name].read_value()
            socket.set_point_now(name, value)
            live_socket.set_point_now(name, value)
            if loggers[name].read_trigged():
                print(value)
                db_logger.save_point_now(name, value)
                loggers[name].clear_trigged()
开发者ID:CINF,项目名称:PyExpLabSys,代码行数:44,代码来源:voltage_logger.py

示例14: main

def main():
    """ Main function """
    logging.basicConfig(filename="logger.txt", level=logging.ERROR)
    logging.basicConfig(level=logging.ERROR)
    ports = '/dev/ttyUSB0'
    xgs_instance = xgs600.XGS600Driver(ports)
    print(xgs_instance.read_all_pressures())

    pressure = PressureReader(xgs_instance)
    pressure.start()

    time.sleep(2.5)

    codenames = ['tof_iongauge_ft', 'tof_iongauge_main', 'tof_pirani_roughing']
    loggers = {}
    loggers[codenames[0]] = ValueLogger(pressure, comp_val=0.1,
                                        low_comp=1e-11, comp_type='log', channel=0)
    loggers[codenames[0]].start()
    loggers[codenames[1]] = ValueLogger(pressure, comp_val=0.1, comp_type='log', channel=1)
    loggers[codenames[1]].start()
    loggers[codenames[2]] = ValueLogger(pressure, comp_val=0.1, comp_type='log', channel=2)
    loggers[codenames[2]].start()

    livesocket = LiveSocket('TOF data logger', codenames, 2)
    livesocket.start()

    db_logger = ContinuousDataSaver(continuous_data_table='dateplots_tof',
                                    username=credentials.user,
                                    password=credentials.passwd,
                                    measurement_codenames=codenames)
    db_logger.start()

    while pressure.isAlive():
        time.sleep(0.5)
        for name in codenames:
            value = loggers[name].read_value()
            livesocket.set_point_now(name, value)
            if loggers[name].read_trigged():
                print(value)
                db_logger.save_point_now(name, value)
                loggers[name].clear_trigged()
开发者ID:jlopezBolt,项目名称:PyExpLabSys,代码行数:41,代码来源:datalogger.py

示例15: test_enqueue_point

    def test_enqueue_point(self):
        """Test the continous logger by sending data with timestamps"""
        # Make timestamps to use
        number_of_points = 10
        start = time.time()
        times = [start + increment for increment in range(number_of_points)]

        # Form the lists for local storage of data, for tests
        data1 = []
        data2 = []

        # Init the db_saver
        db_saver = ContinuousDataSaver("dateplots_dummy", "dummy", "dummy", ["dummy_sine_one", "dummy_sine_two"])
        db_saver.start()

        # Save the points
        for now in times:
            value = math.sin(now)
            data1.append([now, value])
            db_saver.save_point("dummy_sine_one", (now, value))
            value = math.sin(now + math.pi)
            data2.append([now, value])
            db_saver.save_point("dummy_sine_two", (now, value))

        # Make sure the queue has been cleared
        while db_saver.sql_saver.queue.qsize() > 0:
            time.sleep(0.01)

        # Get the measurement code numbers from the logger
        codes = (db_saver.codename_translation["dummy_sine_one"], db_saver.codename_translation["dummy_sine_two"])

        # Check if the data has been properly written to the db
        for data, code in zip((data1, data2), codes):
            query = (
                "SELECT UNIX_TIMESTAMP(time), value FROM dateplots_dummy "
                "WHERE type={} ORDER BY id DESC LIMIT {}".format(code, number_of_points)
            )
            CURSOR.execute(query)
            fetched = reversed(CURSOR.fetchall())
            for point_original, point_control in zip(data, fetched):
                # Time is rounded, so it is only correct to within ~0.51 s
                assert np.isclose(point_original[0], point_control[0], atol=0.51)
                assert np.isclose(point_original[1], point_control[1])

        db_saver.stop()
开发者ID:CINF,项目名称:PyExpLabSys,代码行数:45,代码来源:test_database_saver.py