本文整理汇总了C++中ThermalZone::model方法的典型用法代码示例。如果您正苦于以下问题:C++ ThermalZone::model方法的具体用法?C++ ThermalZone::model怎么用?C++ ThermalZone::model使用的例子?那么恭喜您, 这里精选的方法代码示例或许可以为您提供帮助。您也可以进一步了解该方法所在类ThermalZone
的用法示例。
在下文中一共展示了ThermalZone::model方法的7个代码示例,这些例子默认根据受欢迎程度排序。您可以为喜欢或者感觉有用的代码点赞,您的评价将有助于系统推荐出更棒的C++代码示例。
示例1: ModelObject
ZoneMixing::ZoneMixing(const ThermalZone& zone)
: ModelObject(ZoneMixing::iddObjectType(), zone.model())
{
OS_ASSERT(getImpl<detail::ZoneMixing_Impl>());
bool ok = setPointer(OS_ZoneMixingFields::ZoneName, zone.handle());
OS_ASSERT(ok);
ok = setPointer(OS_ZoneMixingFields::ScheduleName, zone.model().alwaysOnContinuousSchedule().handle());
OS_ASSERT(ok);
ok = setDesignFlowRate(0.0);
OS_ASSERT(ok);
}
示例2: ModelObject
ZoneHVACEquipmentList::ZoneHVACEquipmentList(const ThermalZone & thermalZone)
: ModelObject(ZoneHVACEquipmentList::iddObjectType(),thermalZone.model())
{
OS_ASSERT(getImpl<detail::ZoneHVACEquipmentList_Impl>());
setPointer(OS_ZoneHVAC_EquipmentListFields::ThermalZone,thermalZone.handle());
}
示例3: addToThermalZone
bool RefrigerationAirChiller_Impl::addToThermalZone(ThermalZone & thermalZone)
{
Model m = this->model();
if( thermalZone.model() != m )
{
return false;
}
removeFromThermalZone();
thermalZone.setUseIdealAirLoads(false);
thermalZone.addEquipment(this->getObject<ZoneHVACComponent>());
return true;
}
示例4: addToThermalZone
bool ZoneHVACBaseboardConvectiveElectric_Impl::addToThermalZone(ThermalZone & thermalZone)
{
Model m = this->model();
if( thermalZone.model() != m )
{
return false;
}
if( thermalZone.isPlenum() )
{
return false;
}
removeFromThermalZone();
thermalZone.setUseIdealAirLoads(false);
thermalZone.addEquipment(this->getObject<ZoneHVACComponent>());
return true;
}
示例5: addToThermalZone
//reimplemented to override the base-class method in ZoneHVACComponent
//because this component doesn't get attached to the zone inlet and zone outlet nodes
bool ZoneHVACLowTempRadiantVarFlow_Impl::addToThermalZone(ThermalZone & thermalZone)
{
Model m = this->model();
if( thermalZone.model() != m )
{
return false;
}
if( thermalZone.isPlenum() )
{
return false;
}
removeFromThermalZone();
thermalZone.setUseIdealAirLoads(false);
thermalZone.addEquipment(this->getObject<ZoneHVACComponent>());
return true;
}
示例6: addToThermalZone
bool ZoneHVACComponent_Impl::addToThermalZone(ThermalZone & thermalZone)
{
Model m = this->model();
if( thermalZone.model() != m ) {
return false;
}
if( thermalZone.isPlenum() ) {
return false;
}
removeFromThermalZone();
thermalZone.setUseIdealAirLoads(false);
// Connect nodes if this is an air based zone hvac component
if( inletPort() != 0u && outletPort() != 0u ) {
// Exhaust Node
Node exhaustNode(m);
PortList exhaustPortList = thermalZone.exhaustPortList();
unsigned nextPort = exhaustPortList.nextPort();
m.connect(exhaustPortList,nextPort,exhaustNode,exhaustNode.inletPort());
ModelObject mo = this->getObject<ModelObject>();
m.connect(exhaustNode,exhaustNode.outletPort(),mo,this->inletPort());
// Air Inlet Node
Node airInletNode(m);
PortList inletPortList = thermalZone.inletPortList();
unsigned nextInletPort = inletPortList.nextPort();
m.connect(airInletNode,airInletNode.outletPort(),inletPortList,nextInletPort);
m.connect(mo,this->outletPort(),airInletNode,airInletNode.inletPort());
}
thermalZone.addEquipment(this->getObject<ZoneHVACComponent>());
return true;
}
示例7: addToThermalZone
bool FanZoneExhaust_Impl::addToThermalZone(ThermalZone & thermalZone)
{
Model m = this->model();
if( thermalZone.model() != m )
{
return false;
}
removeFromThermalZone();
thermalZone.setUseIdealAirLoads(false);
// Zone Exhaust Node (Exhaust Fan Inlet node)
Node exhaustNode(m);
PortList exhaustPortList = thermalZone.exhaustPortList();
unsigned nextPort = exhaustPortList.nextPort();
m.connect(exhaustPortList,nextPort,exhaustNode,exhaustNode.inletPort());
ModelObject mo = this->getObject<ModelObject>();
m.connect(exhaustNode,exhaustNode.outletPort(),mo,this->inletPort());
// Node (Exhaust Fan Outlet Node)
Node exhaustFanOutletNode(m);
m.connect(mo,this->outletPort(),exhaustFanOutletNode,exhaustFanOutletNode.inletPort());
thermalZone.addEquipment(this->getObject<ZoneHVACComponent>());
return true;
}