當前位置: 首頁>>代碼示例>>Python>>正文


Python OpTestHost.host_gather_opal_msg_log方法代碼示例

本文整理匯總了Python中common.OpTestHost.OpTestHost.host_gather_opal_msg_log方法的典型用法代碼示例。如果您正苦於以下問題:Python OpTestHost.host_gather_opal_msg_log方法的具體用法?Python OpTestHost.host_gather_opal_msg_log怎麽用?Python OpTestHost.host_gather_opal_msg_log使用的例子?那麽, 這裏精選的方法代碼示例或許可以為您提供幫助。您也可以進一步了解該方法所在common.OpTestHost.OpTestHost的用法示例。


在下文中一共展示了OpTestHost.host_gather_opal_msg_log方法的5個代碼示例,這些例子默認根據受歡迎程度排序。您可以為喜歡或者感覺有用的代碼點讚,您的評價將有助於係統推薦出更棒的Python代碼示例。

示例1: OpTestIPMIReprovision

# 需要導入模塊: from common.OpTestHost import OpTestHost [as 別名]
# 或者: from common.OpTestHost.OpTestHost import host_gather_opal_msg_log [as 別名]
class OpTestIPMIReprovision():
    ##  Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostUser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostIP=None,
                 i_hostUser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir, i_hostIP, i_hostUser, i_hostPasswd)
        self.cv_HOST = OpTestHost(i_hostIP, i_hostUser, i_hostPasswd,i_bmcIP, i_ffdcDir)
        self.cv_SYSTEM = OpTestSystem(i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostIP,
                 i_hostUser, i_hostPasswd)
        self.util = OpTestUtil()
        self.opTestHMIHandling = OpTestHMIHandling(i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostIP,
                 i_hostUser, i_hostPasswd)

    ##
    # @brief This function will cover following test steps
    #        Testcase: NVRAM Partition-IPMI Reprovision
    #        1. Update NVRAM config data with test config data
    #           i.e "nvram --update-config test-name=test-value"

    #        2. Issue an IPMI PNOR Reprovision request command, to reset NVRAM partition to default.
    #        3. Wait for PNOR Reprovision progress to complete(00).
    #        4. Do a Hard reboot(Power OFF/ON) to avoid nvram cache data.
    #        5. Once system booted, check for NVRAM parition whether the test config data
    #           got erased or not.
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_nvram_ipmi_reprovision(self):
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()
        self.cv_HOST.host_run_command("uname -a")
        self.cv_HOST.host_run_command(BMC_CONST.NVRAM_PRINT_CFG)
        print "IPMI_Reprovision: Updating the nvram partition with test cfg data"
        self.cv_HOST.host_run_command(BMC_CONST.NVRAM_UPDATE_CONFIG_TEST_DATA)
        self.cv_HOST.host_run_command(BMC_CONST.NVRAM_PRINT_CFG)
        print "IPMI_Reprovision: issuing ipmi pnor reprovision request"
        self.cv_SYSTEM.sys_issue_ipmi_pnor_reprovision_request()
        print "IPMI_Reprovision: wait for reprovision to complete"
        self.cv_SYSTEM.sys_wait_for_ipmi_pnor_reprovision_to_complete()
        print "IPMI_Reprovision: gathering the opal message logs"
        self.cv_HOST.host_gather_opal_msg_log()
        print "IPMI_Reprovision: Performing a IPMI Power OFF Operation"
        # Perform a IPMI Power OFF Operation(Immediate Shutdown)
        self.cv_IPMI.ipmi_power_off()
        if int(self.cv_SYSTEM.sys_wait_for_standby_state(BMC_CONST.SYSTEM_STANDBY_STATE_DELAY)) == BMC_CONST.FW_SUCCESS:
            print "IPMI_Reprovision: System is in standby/Soft-off state"
        else:
            l_msg = "IPMI_Reprovision: System failed to reach standby/Soft-off state after pnor reprovisioning"
            raise OpTestError(l_msg)

        print "IPMI_Reprovision: Performing a IPMI Power ON Operation"
        # Perform a IPMI Power ON Operation
        self.cv_IPMI.ipmi_power_on()
        self.cv_SYSTEM.sys_check_host_status()
        self.util.PingFunc(self.cv_HOST.ip, BMC_CONST.PING_RETRY_POWERCYCLE)
        l_res = self.cv_HOST.host_run_command(BMC_CONST.NVRAM_PRINT_CFG)
        if l_res.__contains__(BMC_CONST.NVRAM_TEST_DATA):
            l_msg = "NVRAM Partition - IPMI Reprovision not happening, nvram test config data still exists"
            raise OpTestError(l_msg)
        print "NVRAM Partition - IPMI Reprovision is done, cleared the nvram test config data"
        self.cv_HOST.host_gather_opal_msg_log()
        return BMC_CONST.FW_SUCCESS

    ##
    # @brief This function will cover following test steps
    #        Testcase: GARD Partition-IPMI Reprovision
    #        1. Inject core checkstop using existed function from OpTestHMIHandling.py
    #        2. Do a Hard reboot(IPMI Power OFF/ON)
    #        2. Issue an IPMI PNOR Reprovision request command, to reset GUARD partition to default.
    #        3. Wait for IPMI PNOR Reprovision progress to complete(00).
    #        4. Check for GUARD parition whether the existing gard records erased or not.
    #        6. Reboot the system back to see system is booting fine or not.
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_gard_ipmi_reprovision(self):
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()
        print "IPMI_Reprovision: Injecting system core checkstop to guard the phyisical cpu"
        self.opTestHMIHandling.testHMIHandling(BMC_CONST.HMI_MALFUNCTION_ALERT)
        print "IPMI_Reprovision: Performing a IPMI Power OFF Operation"
        # Perform a IPMI Power OFF Operation(Immediate Shutdown)
        self.cv_IPMI.ipmi_power_off()
        if int(self.cv_SYSTEM.sys_wait_for_standby_state(BMC_CONST.SYSTEM_STANDBY_STATE_DELAY)) == BMC_CONST.FW_SUCCESS:
            print "IPMI_Reprovision: System is in standby/Soft-off state"
        else:
#.........這裏部分代碼省略.........
開發者ID:open-power,項目名稱:op-test-framework,代碼行數:103,代碼來源:OpTestIPMIReprovision.py

示例2: OpTestFWTS

# 需要導入模塊: from common.OpTestHost import OpTestHost [as 別名]
# 或者: from common.OpTestHost.OpTestHost import host_gather_opal_msg_log [as 別名]
class OpTestFWTS():
    ##  Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir, i_hostip, i_hostuser, i_hostPasswd)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostPasswd, i_bmcIP, i_ffdcDir)
        self.cv_SYSTEM = OpTestSystem(i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostip,
                 i_hostuser, i_hostPasswd)
        self.util = OpTestUtil()
        self.user = i_hostuser
        self.ip = i_hostip
        self.passwd = i_hostPasswd


    ##
    # @brief This function just brings the system to host OS.
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_system_reboot(self):
        print "Testing FWTS: Booting system to OS"
        print "Performing a IPMI Power OFF Operation"
        # Perform a IPMI Power OFF Operation(Immediate Shutdown)
        self.cv_IPMI.ipmi_power_off()
        if int(self.cv_SYSTEM.sys_wait_for_standby_state(BMC_CONST.SYSTEM_STANDBY_STATE_DELAY)) == BMC_CONST.FW_SUCCESS:
            print "System is in standby/Soft-off state"
        else:
            l_msg = "System failed to reach standby/Soft-off state"
            raise OpTestError(l_msg)

        self.cv_IPMI.ipmi_power_on()
        self.cv_SYSTEM.sys_check_host_status()
        self.util.PingFunc(self.cv_HOST.ip, BMC_CONST.PING_RETRY_POWERCYCLE)
        self.cv_IPMI.clear_ssh_keys(self.cv_HOST.ip)

        print "Gathering the OPAL msg logs"
        self.cv_HOST.host_gather_opal_msg_log()
        return BMC_CONST.FW_SUCCESS

    ##
    # @brief This function just executes the fwts_execution.sh on host OS
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_fwts(self):
        l_oslevel = self.cv_HOST.host_get_OS_Level()
        if not "Ubuntu" in l_oslevel:
            return
        # Copy the fwts execution file to the tmp folder in the host
        base_path = (os.path.dirname(os.path.abspath(__file__))).split('testcases')[0]
        fwts_script = base_path + "/testcases/fwts_execution.sh"
        try:
            self.util.copyFilesToDest(fwts_script, self.user,
                                             self.ip, "/tmp/", self.passwd)
        except:
            l_msg = "Copying fwts file to host failed"
            print l_msg
            raise OpTestError(l_msg)

        l_res = self.cv_HOST.host_run_command("/tmp/fwts_execution.sh")
        print l_res
開發者ID:open-power,項目名稱:op-test-framework,代碼行數:79,代碼來源:OpTestFWTS.py

示例3: OpTestMCColdResetEffects

# 需要導入模塊: from common.OpTestHost import OpTestHost [as 別名]
# 或者: from common.OpTestHost.OpTestHost import host_gather_opal_msg_log [as 別名]
class OpTestMCColdResetEffects():
    ##  Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostIP The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostPasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostPasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir, i_hostip, i_hostuser, i_hostPasswd)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostPasswd, i_bmcIP, i_ffdcDir)
        self.cv_SYSTEM = OpTestSystem(i_bmcIP, i_bmcUser, i_bmcPasswd,
                                      i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostip,
                                      i_hostuser, i_hostPasswd)
        self.util = OpTestUtil()

        self.opTestSensors = OpTestSensors(i_bmcIP, i_bmcUser, i_bmcPasswd,
                                           i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostip,
                                           i_hostuser, i_hostPasswd)

    ##
    # @brief  This function will test BMC Cold reset vs Host FW status
    #         1. When system is in runtime issue BMC Cold reset.
    #         2. Check Host FW services and drivers.
    #         3. Run sensors command
    #         4. Get list of chips
    #         5. This is expected to fail.
    #           https://github.com/open-power/op-build/issues/482
    #         6. Reboot the system at the end of test.
    #
    # @return BMC_CONST.FW_SUCCESS or BMC_CONST.FW_FAILED
    #
    def test_bmc_cold_reset_effects(self):
        print "Test BMC Cold reset effects versus Host Firmware Status"
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()
        print "Issue BMC Cold reset"
        result = True
        try:
            self.cv_SYSTEM.sys_cold_reset_bmc()
            l_dir = BMC_CONST.SKIBOOT_WORKING_DIR
            self.cv_HOST.host_clone_skiboot_source(l_dir)
            self.cv_HOST.host_compile_xscom_utilities(l_dir)
            l_con = self.cv_SYSTEM.sys_get_ipmi_console()
            self.cv_IPMI.ipmi_host_login(l_con)
            self.cv_IPMI.ipmi_host_set_unique_prompt(l_con)
            self.cv_IPMI.run_host_cmd_on_ipmi_console("uname -a")
            self.cv_IPMI.run_host_cmd_on_ipmi_console("cd %s/external/xscom-utils/; ./getscom -l" % l_dir)
            self.opTestSensors.test_hwmon_driver()
            self.cv_SYSTEM.sys_ipmi_close_console(l_con)
        except:
            result = False
            pass
        print "Gathering the OPAL msg logs"
        self.cv_HOST.host_gather_opal_msg_log()
        self.cv_IPMI.ipmi_power_off()
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()
        if result is False:
            raise OpTestError("MC Cold reset vs Host FW Test failed")
開發者ID:open-power,項目名稱:op-test-framework,代碼行數:70,代碼來源:OpTestMCColdResetEffects.py

示例4: OpTestHMIHandling

# 需要導入模塊: from common.OpTestHost import OpTestHost [as 別名]
# 或者: from common.OpTestHost.OpTestHost import host_gather_opal_msg_log [as 別名]

#.........這裏部分代碼省略.........
            if len(self.l_dic) == 1:
                l_msg = "This is a single chip system, TOD Error recovery won't work"
                print l_msg
                return BMC_CONST.FW_SUCCESS
            elif len(self.l_dic) > 1:
                self.test_tod_errors(BMC_CONST.PSS_HAMMING_DISTANCE)
                self.test_tod_errors(BMC_CONST.INTERNAL_PATH_OR_PARITY_ERROR)
                self.test_tod_errors(BMC_CONST.TOD_DATA_PARITY_ERROR)
                self.test_tod_errors(BMC_CONST.TOD_SYNC_CHECK_ERROR)
                self.test_tod_errors(BMC_CONST.FSM_STATE_PARITY_ERROR)
                self.test_tod_errors(BMC_CONST.MASTER_PATH_CONTROL_REGISTER)
                self.test_tod_errors(BMC_CONST.PORT_0_PRIMARY_CONFIGURATION_REGISTER)
                self.test_tod_errors(BMC_CONST.PORT_1_PRIMARY_CONFIGURATION_REGISTER)
                self.test_tod_errors(BMC_CONST.PORT_0_SECONDARY_CONFIGURATION_REGISTER)
                self.test_tod_errors(BMC_CONST.PORT_1_SECONDARY_CONFIGURATION_REGISTER)
                self.test_tod_errors(BMC_CONST.SLAVE_PATH_CONTROL_REGISTER)
                self.test_tod_errors(BMC_CONST.INTERNAL_PATH_CONTROL_REGISTER)
                self.test_tod_errors(BMC_CONST.PR_SC_MS_SL_CONTROL_REGISTER)
            else:
                l_msg = "Getting Chip information failed"
                raise OpTestError(l_msg)
        elif l_test == BMC_CONST.TFMR_ERRORS:
            self.testTFMR_Errors(BMC_CONST.TB_PARITY_ERROR)
            self.testTFMR_Errors(BMC_CONST.TFMR_PARITY_ERROR)
            self.testTFMR_Errors(BMC_CONST.TFMR_HDEC_PARITY_ERROR)
            self.testTFMR_Errors(BMC_CONST.TFMR_DEC_PARITY_ERROR)
            self.testTFMR_Errors(BMC_CONST.TFMR_PURR_PARITY_ERROR)
            self.testTFMR_Errors(BMC_CONST.TFMR_SPURR_PARITY_ERROR)
        else:
            l_msg = "Please provide valid test case"
            raise OpTestError(l_msg)
        self.cv_SYSTEM.sys_ipmi_close_console(l_con)
        print "Gathering the OPAL msg logs"
        self.cv_HOST.host_gather_opal_msg_log()
        return BMC_CONST.FW_SUCCESS

    ##
    # @brief This function is used to test HMI: processor recovery done
    #        and also this function injecting error on all the cpus one by one and 
    #        verify whether cpu is recovered or not.
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def test_proc_recv_done(self):
        for l_pair in self.l_dic:
            l_chip = l_pair[0]
            for l_core in l_pair[1]:
                l_reg = "1%s013100" % l_core
                l_cmd = "./putscom -c %s %s 0000000000100000; echo $?" % (l_chip, l_reg)

                self.cv_IPMI.run_host_cmd_on_ipmi_console("dmesg -C")
                time.sleep(10)
                l_res = self.cv_IPMI.run_host_cmd_on_ipmi_console(l_cmd)
                time.sleep(10)
                if l_res[-1] == "0":
                    print "Injected thread hang recoverable error"
                elif l_res[-1] == "1":
                    # putscom returns -5 when it is trying to read from write only access register,
                    # In these cases we should not exit and we will contiue with other error injetions
                    continue
                else:
                    if any("Kernel panic - not syncing" in line for line in l_res):
                        l_msg = "Processor recovery failed: Kernel got panic"
                    elif any("Petitboot" in line for line in l_res):
                        l_msg = "System reached petitboot:Processor recovery failed"
                    elif any("ISTEP" in line for line in l_res):
開發者ID:open-power,項目名稱:op-test-framework,代碼行數:70,代碼來源:OpTestHMIHandling.py

示例5: OpTestSystemBootSequence

# 需要導入模塊: from common.OpTestHost import OpTestHost [as 別名]
# 或者: from common.OpTestHost.OpTestHost import host_gather_opal_msg_log [as 別名]
class OpTestSystemBootSequence():
    ##  Initialize this object
    #  @param i_bmcIP The IP address of the BMC
    #  @param i_bmcUser The userid to log into the BMC with
    #  @param i_bmcPasswd The password of the userid to log into the BMC with
    #  @param i_bmcUserIpmi The userid to issue the BMC IPMI commands with
    #  @param i_bmcPasswdIpmi The password of BMC IPMI userid
    #  @param i_ffdcDir Optional param to indicate where to write FFDC
    #
    # "Only required for inband tests" else Default = None
    # @param i_hostip The IP address of the HOST
    # @param i_hostuser The userid to log into the HOST
    # @param i_hostpasswd The password of the userid to log into the HOST with
    #
    def __init__(self, i_bmcIP, i_bmcUser, i_bmcPasswd,
                 i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir=None, i_hostip=None,
                 i_hostuser=None, i_hostpasswd=None):
        self.cv_BMC = OpTestBMC(i_bmcIP, i_bmcUser, i_bmcPasswd, i_ffdcDir)
        self.cv_IPMI = OpTestIPMI(i_bmcIP, i_bmcUserIpmi, i_bmcPasswdIpmi,
                                  i_ffdcDir, i_hostip, i_hostuser, i_hostpasswd)
        self.cv_HOST = OpTestHost(i_hostip, i_hostuser, i_hostpasswd, i_bmcIP, i_ffdcDir)
        self.cv_SYSTEM = OpTestSystem(i_bmcIP, i_bmcUser, i_bmcPasswd,
                         i_bmcUserIpmi, i_bmcPasswdIpmi, i_ffdcDir, i_hostip,
                         i_hostuser, i_hostpasswd)
        self.util = OpTestUtil()

    ##
    # @brief This function will test mc cold reset boot sequence
    #        It has below steps
    #        1. Do a system Power OFF(Host should go down)
    #        2. Set auto reboot policy to off(chassis policy always-off)
    #        3. Issue a BMC Cold reset.
    #        4. After BMC comes up, Issue a Power ON of the system
    #        5. Check for system status and gather OPAL msg log.
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def testMcColdResetBootSequence(self):
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()
        print "Testing MC Cold reset boot sequence"
        print "Performing a IPMI Power OFF Operation"
        # Perform a IPMI Power OFF Operation(Immediate Shutdown)
        self.cv_IPMI.ipmi_power_off()
        if int(self.cv_SYSTEM.sys_wait_for_standby_state(BMC_CONST.SYSTEM_STANDBY_STATE_DELAY)) == 0:
            print "System is in standby/Soft-off state"
        else:
            l_msg = "System failed to reach standby/Soft-off state"
            raise OpTestError(l_msg)
        print "Setting the system power policy to always-off"
        self.cv_IPMI.ipmi_set_power_policy("always-off")

        # Perform a BMC Cold Reset Operation
        self.cv_IPMI.ipmi_cold_reset()

        print "Performing a IPMI Power ON Operation"
        # Perform a IPMI Power ON Operation
        self.cv_IPMI.ipmi_power_on()
        self.cv_SYSTEM.sys_check_host_status()
        self.util.PingFunc(self.cv_HOST.ip, BMC_CONST.PING_RETRY_POWERCYCLE)
        self.cv_IPMI.clear_ssh_keys(self.cv_HOST.ip)

        print "Gathering the OPAL msg logs"
        self.cv_HOST.host_gather_opal_msg_log()
        return BMC_CONST.FW_SUCCESS

    ##
    # @brief This function will test mc warm reset boot sequence
    #        It has below steps
    #        1. Do a system Power OFF(Host should go down)
    #        2. Set auto reboot policy to off(chassis policy always-off)
    #        3. Issue a BMC Warm reset.
    #        4. After BMC comes up, Issue a Power ON of the system
    #        5. Check for system status and gather OPAL msg log.
    #
    # @return BMC_CONST.FW_SUCCESS or raise OpTestError
    #
    def testMcWarmResetBootSequence(self):
        self.cv_SYSTEM.sys_bmc_power_on_validate_host()
        print "Testing MC Warm reset boot sequence"
        print "Performing a IPMI Power OFF Operation"
        # Perform a IPMI Power OFF Operation(Immediate Shutdown)
        self.cv_IPMI.ipmi_power_off()
        if int(self.cv_SYSTEM.sys_wait_for_standby_state(BMC_CONST.SYSTEM_STANDBY_STATE_DELAY)) == 0:
            print "System is in standby/Soft-off state"
        else:
            l_msg = "System failed to reach standby/Soft-off state"
            raise OpTestError(l_msg)
        print "Setting the system power policy to always-off"
        self.cv_IPMI.ipmi_set_power_policy("always-off")

        # Perform a BMC Warm Reset Operation
        self.cv_IPMI.ipmi_warm_reset()

        print "Performing a IPMI Power ON Operation"
        # Perform a IPMI Power ON Operation
        self.cv_IPMI.ipmi_power_on()
        self.cv_SYSTEM.sys_check_host_status()
        self.util.PingFunc(self.cv_HOST.ip, BMC_CONST.PING_RETRY_POWERCYCLE)
        self.cv_IPMI.clear_ssh_keys(self.cv_HOST.ip)

#.........這裏部分代碼省略.........
開發者ID:open-power,項目名稱:op-test-framework,代碼行數:103,代碼來源:OpTestSystemBootSequence.py


注:本文中的common.OpTestHost.OpTestHost.host_gather_opal_msg_log方法示例由純淨天空整理自Github/MSDocs等開源代碼及文檔管理平台,相關代碼片段篩選自各路編程大神貢獻的開源項目,源碼版權歸原作者所有,傳播和使用請參考對應項目的License;未經允許,請勿轉載。