本文整理匯總了Golang中bootstrap/link/internal/ld.Reloc.Type方法的典型用法代碼示例。如果您正苦於以下問題:Golang Reloc.Type方法的具體用法?Golang Reloc.Type怎麽用?Golang Reloc.Type使用的例子?那麽, 這裏精選的方法代碼示例或許可以為您提供幫助。您也可以進一步了解該方法所在類bootstrap/link/internal/ld.Reloc
的用法示例。
在下文中一共展示了Reloc.Type方法的2個代碼示例,這些例子默認根據受歡迎程度排序。您可以為喜歡或者感覺有用的代碼點讚,您的評價將有助於係統推薦出更棒的Golang代碼示例。
示例1: adddynrel
func adddynrel(s *ld.LSym, r *ld.Reloc) {
targ := r.Sym
ld.Ctxt.Cursym = s
switch r.Type {
default:
if r.Type >= 256 {
ld.Diag("unexpected relocation type %d", r.Type)
return
}
// Handle relocations found in ELF object files.
case 256 + ld.R_X86_64_PC32:
if targ.Type == obj.SDYNIMPORT {
ld.Diag("unexpected R_X86_64_PC32 relocation for dynamic symbol %s", targ.Name)
}
if targ.Type == 0 || targ.Type == obj.SXREF {
ld.Diag("unknown symbol %s in pcrel", targ.Name)
}
r.Type = obj.R_PCREL
r.Add += 4
return
case 256 + ld.R_X86_64_PLT32:
r.Type = obj.R_PCREL
r.Add += 4
if targ.Type == obj.SDYNIMPORT {
addpltsym(targ)
r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0)
r.Add += int64(targ.Plt)
}
return
case 256 + ld.R_X86_64_GOTPCREL, 256 + ld.R_X86_64_GOTPCRELX, 256 + ld.R_X86_64_REX_GOTPCRELX:
if targ.Type != obj.SDYNIMPORT {
// have symbol
if r.Off >= 2 && s.P[r.Off-2] == 0x8b {
// turn MOVQ of GOT entry into LEAQ of symbol itself
s.P[r.Off-2] = 0x8d
r.Type = obj.R_PCREL
r.Add += 4
return
}
}
// fall back to using GOT and hope for the best (CMOV*)
// TODO: just needs relocation, no need to put in .dynsym
addgotsym(targ)
r.Type = obj.R_PCREL
r.Sym = ld.Linklookup(ld.Ctxt, ".got", 0)
r.Add += 4
r.Add += int64(targ.Got)
return
case 256 + ld.R_X86_64_64:
if targ.Type == obj.SDYNIMPORT {
ld.Diag("unexpected R_X86_64_64 relocation for dynamic symbol %s", targ.Name)
}
r.Type = obj.R_ADDR
return
// Handle relocations found in Mach-O object files.
case 512 + ld.MACHO_X86_64_RELOC_UNSIGNED*2 + 0,
512 + ld.MACHO_X86_64_RELOC_SIGNED*2 + 0,
512 + ld.MACHO_X86_64_RELOC_BRANCH*2 + 0:
// TODO: What is the difference between all these?
r.Type = obj.R_ADDR
if targ.Type == obj.SDYNIMPORT {
ld.Diag("unexpected reloc for dynamic symbol %s", targ.Name)
}
return
case 512 + ld.MACHO_X86_64_RELOC_BRANCH*2 + 1:
if targ.Type == obj.SDYNIMPORT {
addpltsym(targ)
r.Sym = ld.Linklookup(ld.Ctxt, ".plt", 0)
r.Add = int64(targ.Plt)
r.Type = obj.R_PCREL
return
}
fallthrough
// fall through
case 512 + ld.MACHO_X86_64_RELOC_UNSIGNED*2 + 1,
512 + ld.MACHO_X86_64_RELOC_SIGNED*2 + 1,
512 + ld.MACHO_X86_64_RELOC_SIGNED_1*2 + 1,
512 + ld.MACHO_X86_64_RELOC_SIGNED_2*2 + 1,
512 + ld.MACHO_X86_64_RELOC_SIGNED_4*2 + 1:
r.Type = obj.R_PCREL
if targ.Type == obj.SDYNIMPORT {
ld.Diag("unexpected pc-relative reloc for dynamic symbol %s", targ.Name)
}
return
case 512 + ld.MACHO_X86_64_RELOC_GOT_LOAD*2 + 1:
//.........這裏部分代碼省略.........
示例2: archreloc
func archreloc(r *ld.Reloc, s *ld.LSym, val *int64) int {
if ld.Linkmode == ld.LinkExternal {
switch r.Type {
default:
return -1
case obj.R_ARM64_GOTPCREL:
var o1, o2 uint32
if ld.Ctxt.Arch.ByteOrder == binary.BigEndian {
o1 = uint32(*val >> 32)
o2 = uint32(*val)
} else {
o1 = uint32(*val)
o2 = uint32(*val >> 32)
}
// Any relocation against a function symbol is redirected to
// be against a local symbol instead (see putelfsym in
// symtab.go) but unfortunately the system linker was buggy
// when confronted with a R_AARCH64_ADR_GOT_PAGE relocation
// against a local symbol until May 2015
// (https://sourceware.org/bugzilla/show_bug.cgi?id=18270). So
// we convert the adrp; ld64 + R_ARM64_GOTPCREL into adrp;
// add + R_ADDRARM64.
if !(r.Sym.Version != 0 || (r.Sym.Type&obj.SHIDDEN != 0) || r.Sym.Local) && r.Sym.Type == obj.STEXT && ld.DynlinkingGo() {
if o2&0xffc00000 != 0xf9400000 {
ld.Ctxt.Diag("R_ARM64_GOTPCREL against unexpected instruction %x", o2)
}
o2 = 0x91000000 | (o2 & 0x000003ff)
r.Type = obj.R_ADDRARM64
}
if ld.Ctxt.Arch.ByteOrder == binary.BigEndian {
*val = int64(o1)<<32 | int64(o2)
} else {
*val = int64(o2)<<32 | int64(o1)
}
fallthrough
case obj.R_ADDRARM64:
r.Done = 0
// set up addend for eventual relocation via outer symbol.
rs := r.Sym
r.Xadd = r.Add
for rs.Outer != nil {
r.Xadd += ld.Symaddr(rs) - ld.Symaddr(rs.Outer)
rs = rs.Outer
}
if rs.Type != obj.SHOSTOBJ && rs.Type != obj.SDYNIMPORT && rs.Sect == nil {
ld.Diag("missing section for %s", rs.Name)
}
r.Xsym = rs
// Note: ld64 currently has a bug that any non-zero addend for BR26 relocation
// will make the linking fail because it thinks the code is not PIC even though
// the BR26 relocation should be fully resolved at link time.
// That is the reason why the next if block is disabled. When the bug in ld64
// is fixed, we can enable this block and also enable duff's device in cmd/7g.
if false && ld.HEADTYPE == obj.Hdarwin {
var o0, o1 uint32
if ld.Ctxt.Arch.ByteOrder == binary.BigEndian {
o0 = uint32(*val >> 32)
o1 = uint32(*val)
} else {
o0 = uint32(*val)
o1 = uint32(*val >> 32)
}
// Mach-O wants the addend to be encoded in the instruction
// Note that although Mach-O supports ARM64_RELOC_ADDEND, it
// can only encode 24-bit of signed addend, but the instructions
// supports 33-bit of signed addend, so we always encode the
// addend in place.
o0 |= (uint32((r.Xadd>>12)&3) << 29) | (uint32((r.Xadd>>12>>2)&0x7ffff) << 5)
o1 |= uint32(r.Xadd&0xfff) << 10
r.Xadd = 0
// when laid out, the instruction order must always be o1, o2.
if ld.Ctxt.Arch.ByteOrder == binary.BigEndian {
*val = int64(o0)<<32 | int64(o1)
} else {
*val = int64(o1)<<32 | int64(o0)
}
}
return 0
case obj.R_CALLARM64,
obj.R_ARM64_TLS_LE,
obj.R_ARM64_TLS_IE:
r.Done = 0
r.Xsym = r.Sym
r.Xadd = r.Add
return 0
}
}
switch r.Type {
case obj.R_CONST:
*val = r.Add
//.........這裏部分代碼省略.........